Blog

Coltraco Commitment To :

  • Through-life maintenance support
  • We still maintain units built 20 years ago
  • Extend trade-in credits - replace old units for new
  • UL listing & ABS type approval - Portalevel™ MAX
  • ABS type approval & RINA approval - Portascanner™
  • Be a life-safety technology partner – Permalevel™
  • Certified OEM calibration & ODA service stations

Coltraco manufacture Ultrasonics That Work

What features does the Portalevel® Standard have?

  • Measurements:
  • Width: 95 mm (3.74 inches)
  • Height: 155 mm (6.10 inches)
  • Weight: 500 grams (17.63 ounces)
  • Profundity: 45 mm (1.77 inches)
  • Precision:

+/ - 1.5mm or 1/8 inch

  • Irrefutable Agents: FM 200™, CO2, H2O, NOVEC™ 1230, Halons, for example, FE-13™, HFC-225 and 2271, FE-36™, FE-25™, 1301 and 1211.
  • Sensor 2: TX/RX Dry Sensor, 14 mm in width containing polarized sensor implement and is associated by BNC connectors to 1 m length co hatchet – link.
  • Power Supply: It accompanies the power supply of 4 x AA 1.5 V batteries which work for 10 hours.
  • Display: The display demonstrating numeric advanced comes as LCD with LED Bar Graph.
  • Working Temperature: The working temperature for the accompanying gadget is - 20°C to +70°C or 68°F to 158°F) and Relative Humidity is - 5 % - 95 %.
  • Guarantee: 3 years guarantee for the primary unit and one year for the sensor.
  • Characterization: This liquid level indicator have two groups:
  • IP Rating 65
  • NATO Stock Number: 6680-99-275-5292.
  • Bundle Contents: The bundle Portalevel® Standard contains 1 Portalevel Standard unit, Ultrasonic Gel, 1 Wet Sensor, Calibration Certificate, 1 Hard Wearing Carrying Case and Operating Instructions.

What are bearings and how are they used?

Bearings are an integral device widely used in machinery that requires rotational, axial or linear movement to operate whilst restricting motion into a designed path, minimizing friction and stress. Many industries have machinery that requires some form of motion enabled by bearings. Such as:

Steel production facilities

Steel and iron use cold rolling mill machi-nery. The working rolls of the plant are the most extensively monitored. This is quite a challenging monitoring environment due to high temperatures, high and low-speed operation, as well as high contamination of water and debris.

Mining industry

Slow turning rolling element bearings require monitoring in this industry. Machinery such as crushers, stackers, conveyors, vibrating feeders, magnetic separators, slurry and vacuum pumps, classifiers, agitators and compressors.

Paper processing Industry

Papermaking machine bearings operate under very high temperatures and can be vulnerable to fractures of the inner ring, causing stoppages in production. Monitoring is done to determine the condition of the rolling-element bearings of the rolls, roll alignment, balance, and the condition of the electric motors and gearboxes.

Cement industry

Many machines in this industry require monitoring of bearing condition, inclu-ding crushers, mills, separators, roller presses, separators, conveyors, feeders, air compressors and fans. Most of which use rolling-element bearings powered by electric motors.

Thermal power industry

Gas and steam turbine generators and combined cycle plants require their most critical machines monitored. Dynamic rotating machines use high-speed rotating parts. The cost of failure in this industry is far-reaching.

Maritime industry

Diesel engines, gas turbines and nuclear reactor powered ships utilize bearings in all areas, from crankshafts to pistons and pumps. Also, gearboxes fans and other motors onboard, such as alternators used to generate electricity.

Many aspects of ship engines utilize bearings, from crankshafts to pistons and pumps. Also, gearboxes fans and other motors. Almost all machinery that moves requires bearings. However, they are liable to degradation over time and many factors influence this. According to studies conducted by the Mobius Institute defects are encapsulated in the chart below.

We are not investigating these particular categories in detail but we can exclude the handling/Installation section for our purpose, as this is not applicable nor possible to prevent through direct monitoring. The remaining 84% accounts for issues occurring once installed. Monitoring is essential for the detection of faults caused by fatigue or stress due to excessive load or use. Incorrect lubrication, as well as insufficient levels, can cause friction which can lead to fractures among other defects. Also, contamination, both in the bearing housing or the lubrication can damage and reduce the life of bearings.
Monitoring can detect abnormalities caused by these and allow preparations for maintenance or replacement. Ultimately avoiding failure and saving money. The cost of bearings is highly variable and depends on position and if any associated damage has occurred as a result of the initial bearings then figures can rise quickly. In severe cases when bearing monitoring has been limited and total failure has occurred then the cost can be tremendous.

All of the above contain bearings and if not monitored, or repaired when needed. The results could be catastrophic failure. This is just the cost of the replacement machinery, of course, this varies, especially when only small replacements are needed. A failure of a bearing is not just the part itself, the cost to a- vessel owner is repair, fitting and downtime in dock and loss of earning whilst not operational. Needless to say, the process can become extremely expensive.

Why do bearings fail?

Bearings will fail for a number of reasons but the key take away is that ALL bearings will degrade at some point and if they are left unchecked, maintained or replaced WILL fail. Bearing failure can have overwhelming consequences for a business. Appropriate monitoring matters because false diagnosis can result in undue downtime, wasted time, money and resources. The correct diagnosis is also extremely important but can be challenging. Knowing the root cause of damage can help prevent future failures. According to ISO 15243, damages left undiagnosed can actually mask the underlying cause if left too long [ISO 15243]. Below is an example showing the progression of bearing damage that has become more severe, thus hiding the root cause:

Case studie(s)

Many cases of catastrophic failure in bearings have occurred throughout the industry that could have been avoided if effective condition monitoring and maintenance had been in place. The following case study of bearing failure has been taken from the Australian Transport Safety Bureau:

On 7 March 1997, the Polish flag general cargo vessel Lodz 2 was using one of its own cranes, discharging a general cargo of steel products, including bundles of steel pipes, from no. 2 hold and tween deck. At about 0740, the sixth load of steel pipes, for that morning, was being discharged onto the wharf by no.1crane, a 12.5-tonne capacity crane situated on the aft end of the forecastle on the ships centreline. The load, weighing approximately 8.6 tonnes, consisted of 18 lengths with diameters varying up to 273 mm. As the load reached the side of the ship, there was a violent jolt and a bang as the slew bearing failed, then the crane fell from its pedestal into the port tween deck of no. 2 hold.

The jib struck the port bulwark, setting it down and out from the ships side, while the body of the crane hit the inboard edge of the port hatch coaming, before rotating through 180∞ and finishing up, upside-down, in the tween deck. The driver had fallen with the cab of the crane, approximately 17 metres into the tween deck from the cranes position on its pedestal. The crane was severely damaged and the badly twisted jib had to be cut up to remove it from the ship.

https://www.atsb.gov.au/publications/investigation_reports/1997/mair/mair110/

Vibration Analysis

Many devices make use of vibrational analysis for monitoring, for instance, accelerometers. Traditional accelerometers are seismic transducers and rely on piezoceramics, either lead zirconate titanate or single crystals (e.g. quartz, tourmaline). Measuring acceleration via its piezoelectric crystals which convert vibration into an electrical signal is known as the piezoelectric effect. 

These devices function based on the crystals’ natural frequency and can sense a wide range of defect frequencies [typically Hz-20 kHz].

Accelerometers are designed to pick up vibrations as an indicator of defects. Excessive vibrations can indicate a serious problem that requires maintenance before a catastrophic failure occurs. Complex software is then used in conjunction to diagnose machinery faults. This is the basis of VA.

Acoustic Emission

AE is used for effectively monitoring different machine conditions; balanced, unbalanced, misaligned and defecting bearings. Monitoring equipment using AE works on the principle of using transient elastic waves to detect the rapid release of strain energy caused by deformations or damage within the surface of materials. Strains, stresses and impacts produce transient stress (elastic) waves which can be effectively detected and occur in the very early stages of bearing degradation. 
Although traditional acceleration and AE techniques are both used for condition monitoring they apply different methods, cover different aspects of the same problem. They are both reliable within a specific operational range and have significant overlap in capability. In some cases, it is less clear which is more capable. However, extensive studies in both areas have been conducted and each has unique benefits but also various limitations. Both of these aspects will be considered in this paper. The table below summarises some common defects that occur in bearings:

Comparison

Operationally Effective Ranges: Accelerometers have an operational effectiveness within a low to high-frequency range ~ 10 Hz - 30 kHz.

This is suitable for displacement, velocity and acceleration measurements for general vibrational analysis. AE is based on frequencies much higher and with a larger range than what’s capable with VA, AE will operate within ~20 kHz-1 mHz , but more usefully around ~20 kHz-1 mHz.

The immediate advantage of this is that mechanical noise is no longer present in this range. Although frequencies of this level mean that AE is slightly less effective for general monitoring because defects in the advanced stages produce lower frequencies and can sometimes saturate the AE signal, it does mean that the ability to detect defects at a very early stage is possible.

Defect frequencies are highly dependent on machinery designs and component geometry and are also a function of bearing geometry, pitch, roller diameter and the relative speed between raceways. Fortunately AE is less geometrically sensitive. It is important to be able to distinguish between machine noise and defect noise. In order to establish defects using VA, a “base-line” needs to be established from the initial conditions of the machinery and used to indicate an irregular condition by monitoring an overall trend that should highlight anomalies.

This is not an easy task and requires highly technical knowledge as well as being very time-consuming. One drawback when monitoring the general condition of the entire machine is that the overall trend level may not show any significant change if the machine fault is not severe, or the signal is insensitive to the fault. With AE the detection of acoustic pulses are usually independent of any machine noise interference, especially at the high operating frequencies which is ideal when baseline frequencies are not known. This gives confidence that defects will not be missed.

Moreover, experiments conducted to test bearing operation at low speeds s [10-100 rev 〖min〗^(-1)] found that AE is sensitive to loading conditions [McFadden, 1984]. A change in load at constant speed causes an increased output of AE signals. The experiment concluded that typical AE transducers are less suitable to general purpose monitoring, whereas, VA  is very suitable in this area.

However, it has been shown that AE is still effective at low speeds [Alshimmeri, 2017] and can effectively detect bearing defects when previously it was assumed that AE was mainly effective at high speeds. It seems that excessive loading will cause disruptions in the obtained signal as it can affect signal attenuation. It has been found that the attenuation of signal remained constant at higher loads and can now be distinguished fairly easily. The effects of attenuation can vary, as with 3d structures, in general, the amplitude of a propagating acoustic wave will decrease by about 50% every time the distance is doubled from the source. 

Signal output will depend on a few design factors. Distance between bearings and sensor placement, including an air gap can also affect output signal. Acoustic waves propagate significantly slower compared to metallic materials within the air gap. The result is a damped signal which may fall below the sensors detection threshold. This will depend on the strength of the source, distance, material and even sensor placement.

Defects

Bearing defects are essentially random but occur in natural stages and will usually worsen due to dynamical strains on the bearing components. Generally speaking, advanced stage defects will produce high intensity but low-frequency signals. The very early stages of wear occur as a result of minuscule abnormalities, such as very small contaminants in lubrication, or small stresses and deformations in the material. Defects at this stage can only be detected in the very high-frequency range which is covered by AE monitoring.

Contaminants in lubrication will cause mechanical impacts that would traditionally be checked separately using other methods such as listening to frequency changes in conjunction with structural monitoring or with post-processing, such as the Shock Pulse Method (SPM). This will pick up the mechanical shock wave produced when mechanical contact has occurred. This method uses slightly more complicated processes and again needs specialist knowledge.

It has been found that lubrication containing contaminants as small as 500 μm, which would ordinarily be missed using traditional methods produces an AE pulse, detectible by AE monitoring. This is a clear indication of its usefulness of AE in this area compared to traditional methods
Although sources of defects are random in nature, the most important AE source is in the form of cracks because they produce some of the highest frequencies. Cracks cause a displacement of the surrounding material which increases in magnitude and will usually evolve into more serious problems. It has been shown that vibrational analysis will not pick up defects at this stage, as it is beyond the frequency range. Other aspects of monitoring are arguably just as important as crack formation for the prevention of total failure but usually, occur in the later stages when the damage has already occurred.

Post-Processing

Once raw data has been obtained using data-acquisition systems, post-processing takes place in order to clarify findings. A significant difference between the two techniques in question happens at this stage. VA requires the signals to be processed downstream, manually or semi-automatically where complex post-measurement data needs to be interpreted by a specialist. Raw data is commonly analysed using Fast Fourier Transforms (FFT) to determine the sine wave frequencies and respective amplitudes. The peaks in frequencies define the type of fault whilst the amplitudes indicate the severity. This seems unnecessary complex in comparison to the automatic processing at sensor level provided by AE devices.

AE devices commonly use algorithms to derive acoustic emission parameters of Distress® and db levels which give an indication of bearing health and overall noise respectively. This provides immediate clarification of defects and is easier to interpret. AE requires approximately 10 seconds of continuous monitoring at a consistent running speed, whereas FFT based vibrational analysis typically requires 60 – 120 seconds of measurement to establish the same level of knowledge about the defect.
Although analysis of the frequency spectrum using vibrational data appears to be more in-depth and possibly even the best indicator when looking at overall machine conditions, the defect frequency may be close to the frequency excited by the components of the machine, which can lead to misinterpretations.
The totality of information provided by vibrational analysis exceeds that of AE and can be very useful when trying to determine the precise location and nature of advanced defects, however, data acquired using AE can also be analysed in a similar way in order to gain more information, but is usually unnecessary considering AE devices automatically derive vital information automatically at sensor level.

When using AE and more advanced post-processing a detection threshold needs to be established which is based on the number of times the amplitude (determined from the wavelet) exceeds a pre-set voltage within a given time. This threshold (voltage limit) can be adjusted, or floating, depending on the circumstances and machine specifications. Signals below the threshold are discarded allowing faster processing with less data storage. In reality, there are a variety of rotating machines with an even larger variety of operating conditions making the decision to set a lower limit a challenge for AE monitoring.

However, studies have shown that varying values of this threshold that lie within the range of 20%, 30% and 40% of the signal amplitude, are insensitive and doesn’t affect results significantly. Tests have been conducted and show that the probability of misdiagnosis is proved to be very remote, indeed. This indicates that the threshold is mainly effective at removing excess data, thus reducing processing time.

Conclusion

Operationally speaking, both of these monitoring systems can be complementary. However, vibrational analysis can be influenced significantly by the natural frequency of the machinery and VA  is only useful when combined with data acquisition systems and complicated post-processing. Both VA  and AE is useful when investigating low rotational speeds but AE is very effective at detecting deformation due to the formation of cracks or friction which occur in the very early stages that are independent of the machines dynamics. It has been shown that defects give off an AE pulse well before they can be detected by vibrational analysis.

Due to the general evolution of defects in machinery, damage must have already occurred for it to produce a detectible vibrational anomaly which sits in the operational frequency of suitable for VA.  VA is very useful for detecting more advanced stages of defects and for general monitoring of rotational and non-rotational machinery but, is clearly limited when damage occurs beyond the detectable limit and for defects in the very infant stages. Ultimately AE provides the longest period of monitoring.

The importance of being able to operate at very high frequencies is paramount for early detection of defects and for detecting defects when noise levels are high [as is always the case]. Using AE operating at very-high-frequency levels ensures very early detection and enables detection even with high operational noise from the machinery. This allows maintenance teams to schedule appropriate action that minimises operational disruption whilst avoiding catastrophic failure.

Extensive research has been conducted over the past few decades into vibrational analysis and more recently into AE. Overall, it is apparent that VA coupled with complex post-measurement data analysis is useful for general degradation monitoring but can only detect defects that are in the advanced stages, effectively missing arguably the most important stages of defects. VA also requires experienced operators to use and interpret raw data, an unnecessary expense to a company.

AE technology and post-processing has effectively been de-skilled due to its simplicity, meaning it can be used by most operators with relative ease, again reducing the cost for training/hiring specialists, but also, empowering current monitoring staff. I think the research is compelling and clear, early detection and simple diagnosis is key to avoiding catastrophic failure, which is what AE monitoring provides.

Looking forward, it’s clear that AE is far superior for monitoring, it is now a well-established, tried and tested method of defect detection, proven time and time again. Preventative maintenance and early warning systems work and have shown to be more effective. AE is a technology that is making headway in the industry and is a smart choice when it comes to time-saving cost-effective monitoring. The earlier we know that a problem exists the better equipped we are at solving it. AE has a proven track record and can give practitioners and companies confidence that they have the greatest protection in place.

Who are Coltraco Ultrasonics?

Choose Coltraco Ultrasonics for world-leading ultrasonic technology to test your fire suppression systems. With handheld inspection products and constant monitoring systems, you can be confident that your CO2/clean agent/sprinkler systems, etc. will extinguish a fire when needed. Know when your cylinders/pipes are empty/rusting.
We deliver the Safesite®: a holistic approach to save time and cost - improving safety of life, asset and infrastructure. Operating in 109 countries since 1987, this leading British manufacturer of inspection tools and constant monitoring system

  1.  liquefied gaseous agent contents through the most ergonomic and accurate contents indicators (Portalevel® range) and the only capability to convert level readings to agent weight (Portasteele® Calculator); and 24/7 constant monitoring (Permalevel® range);
  2.  pressure of non-liquefied gaseous agent contents;
  3.  the compartment and room integrity into which the agent discharges to ensure the agent can be held and so extinguish the fire event (Portascanner® 520);
  4. their associated pipework
  5. to complete the new FIRETEST™ range of fire products to provide the fire servicing engineer a “basket” of easy and accurate instrumentation across the gaseous, sprinkler and deluge sectors.

Coltraco Ultrasonics are proud exporters, exporting 89% to 109 countries: 40% to Asia, 10% to the Middle East, 15% to Europe, 17% to North America and the balance to South America and Africa. Coltraco Ultrasonics exporters are supported by our global network of Strategic Partners, ODA Service Centres and Distributors. Exporting is at Coltraco’s core and a consequence of conducting fine science and manufacturing in the UK. Great science is based on the integrity of it, and that distinguishes how Coltraco compete.

Coltraco Ultrasonics operate in multiple market sectors: Shipping, Fire, Naval, Offshore, Power Generating, Electricity Distribution, Data Centres, Banks, Telecommunications, Marine Surveying, Rail, Mining, Pharmaceuticals and Food Processing and most recently in Renewable Wind Energy.

We are:

  1. Faster: our ultrasonic technology is designed to be the simplest, most effective method to inspect quickly
  2. Better: we are committed to integrity throughout our company from design, manufacture, supply and after sales support to make sure we are world-leaders
  3. Cheaper: we offer cost effective solutions as well as offering a “never beaten on price guarantee”

What features does the Permalevel® Multiplex have?

Permalevel Multiplex is the first system worldwide that is capable of monitoring the liquid level of critical fire suppression cylinder systems on a constant basis. It gives a facility total visibility on the real-time status of all their critical fire systems.

Modern fire suppression systems have transformed industry safety across all sectors. However, the development of their servicing and monitoring equipment has remained stagnant, with many very advanced systems relying totally on annual inspections, or on unreliable mechanical pressure gauges. These methods leave the status of fire suppression systems completely vulnerable between annual checks.

Coltraco are raising awareness that annual certification checks on a fire system cannot cater for the need to monitor its contents for the rest of the year.
The Permalevel MultiplexTM is designed to ensure that fire suppression systems are always fully operational and that no accidental discharge has occurred, which could affect the effectiveness of the overall fire protection system in the event that it is required for use.

Features of Permalevel Multiplex

MULTIPLE ALARM OPTIONS: a Master Alarm output. The multiplex has an RS232/485 output allowing communication with a central monitoring system or PC

STATUS OF EACH CHANNEL SHOWN BY LEDs: A set of green and red LED lights indicate the status of each cylinder.

TEXT/EMAIL ALERTS: Provide an instantaneous and convenient form of data communication.

UNINTERRUPTABLE POWER SUPPLY: Backup system provides power in the event of mains power failure.

DATALOGGING ABILITY: The software keeps logs of the system activity, errors and alarm trigger on a monthly basis.

STRONG MAGNETS: Hold the sensors in place with additional space for adhesive or a strap to ensure sensors are not accidentally removed. SENSORS: Each monitoring point has its own dedicated sensor which is connected to the cylinder it is monitoring.

REMOTE REAL-TIME MONITORING SCREEN: Displays information about the current status of the cylinders, and when last contact was made.

COMPATIBLE WITH MULTIPLE CYLINDER TYPES: Each channel can be individually tuned, therefore each cylinder can be different from the last in size, weight, pressure and agent type.

Stay ahead with preventative maintenance by using Portamonitor™ Bearing Indicator

Stay ahead by improving your preventative maintenance thanks to including Portamonitor® Bearing Indicator in your management regime. This effective kit provides insight into planning of future repairs. It identifies sites which are contaminated or lacking lubrication so they can be easily fixed before any further damage occurs. Above and beyond that, the Portamonitor® identifies varying levels of damage to prevent excessive and extremely dangerous damage.

 The miniature Portamonitor® has been designed to test bearings and rotating machinery on board ships and naval vessels. Portamonitor® aids in the identification of mechanically deteriorated bearings and bearings with inadequate/contaminated lubricant. It does this by detecting high frequency (ultrasonic) stress waves associated with friction and other faults with machinery in poor condition (impacts etc.). It can be used to monitor bearings in motors, pumps, fans, gearboxes and other rotating machinery applications. It has two outputs – a decibel (dB) reading and a Distress® level which are both measured and displayed simultaneously by the Portamonitor®

 It is extremely sensitive to detecting faults and is easy to use: measurements can be taken both for land-based applications as well as offshore on vessels and platforms. It is quick and reliable, allowing for problem bearings to be checked quickly if damage is suspected. The repeatable results allow the operator to compare logs of past measurements which can help identify even small changes in the functioning of the bearing. The non-destructive and non-intrusive technology will not affect the function of the bearing.

www.coltraco.com/news

Ensure your compartmentation

Would you enter a building if you were told as you stepped in that in the event of a fire there was a chance that the extinguishing system wouldn’t put it out because the fire couldn’t be contained?

No! People expect, and rightfully so, that in the event of a fire the extinguishing systems would be in full working order to do just that – extinguish. Given that the gaseous systems are designed specifically to the individual need of that room, building e.t.c, then a leak sites in the room could meant that the comparted area couldn’t withhold the fire.

The likelihood of the gaseous system effectively extinguishing the fire gets lower and lower as the protected area becomes larger than the size that the extinguishing system was designed for. This is not a game of chance. The lives of people depend upon it. Enough is enough. The technology exists right now to support Door Fan Testing in providing a holistic and thorough integrity test of critical infrastructure.

Key Facts

  • Compartmentation = fire stopping e.g. walls and floors
  • Every 7 seconds, a fire breaks out, worldwide
  • 700 fatalities caused by fire in the UK
  • £7bn is the cost of fire to the UK economy according to GovUK: every day £3.4m in costs by business disruption caused by fire - £1.3bn p.a.
  • 44% of all insurance claims are caused by fire
  • SOURCE: Aviva Insurance, 2012

Regulatory Requirements un-Ravelled

APPROVED DOCUMENT B (ADB)

The regulations demand that compartmentation is upheld for the safety of the individuals, who entrust their lives into its integrity. Approved document B, Fire Safety, Volume 2, Buildings other than dwelling house states that: 8.0 Every compartment wall should form a complete barrier to fire between the compartments they separate. 8.35 – any stairway or other shaft passing directly from one compartment to another should be enclosed in a protected shaft so as to delay or prevent the spread of fire between compartments. However, despite regulations best effort to promote the implementation of compartmentation and room integrity, the last review of the Building Regulations Approved Document B was made in 2006 (12 years ago) and its next review was not due to be completed until 2022 (which would then be a gap of 17 years), meaning that the attention that is deserved is often disregarded.

  • ADB B3-4 “the building shall be designed… so that the unseen spread of fire and smoke… is inhibited”
  • Appendix B Breaching fire separation “to ensure effective protection again fire, walls and floors providing fire separation must form a complete barrier, with an equivalent level of fire resistance provided to any openings such as doors, ventilation ducts, pipe passages or refuge chutes.”

ISO14520-1:2015(E)

We will lead with some extracts from the regulations which is why this paper argues that the industry is sometimes minimally compliant or even non-compliant due to a lack of understanding of fire systems and their connection to compartmentation. This paper calls for a more holistic approach to fire safety. The author suggests the need for a resident mathematician to assist the industry.

  • 9.2.1.3 The storage container contents shall be checked at least every six months. a) Liquefied gases: for halocarbon agents, if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure (adjusted for temperature) of more than 10 %, it shall be refilled or replaced.
  • 9.2.4.1 At least every 12 months it shall be determined whether boundary penetration or other changes to the protected enclosure have occurred that could affect leakage and extinguishant performance. If this cannot be visually determined, it shall be positively established by repeating the test for enclosure integrity in accordance with Annex E.
  • 9.2.4.2 Where the integrity test reveals increased leakage that would result in an inability to retain the extinguishant for the required period, remedial action shall be carried out.
  • A.3.2 Engineered systems: need information and calculations on the amount of extinguishant;
  • Annex F - b) Every 6 months: Perform the following checks and inspections: 5) for liquefied gases, check weigh or use a liquid level indicator to verify correct content of containers; replace or refill any showing a loss of more than 5 %;
  • Annex F 6.2.4.2 Means shall be provided to indicate that each container is correctly charged.

The assumptions in these are that gaseous extinguishing/suppression systems do leak. The regulations that underpin the pursuit of them explore their leak identification every 6 months. Gaseous extinguishing/suppression systems however are installed to protect special hazards in critical infrastructure as their key objective. If the hazard is special and the infrastructure critical then this is the case for the constant monitoring of the suppression systems that aim to deliver the protection of them.

To understand how fire resistant a compartment is, an inspection of the overall condition of the existing fire compartments is needed, as well as an assessment of the condition and effectiveness of the sealing of wall/soffit interfaces and an inspection of existing fire seals applied to service penetrations through fire compartment lines. Issues in the quality of compartmentation walls can come from maintenance, minor works and refurbishments. Contractors carrying out such tasks can occasionally destroy the compartmentation integrity of the wall, floor or ceilings if they were unaware that the area is a comparted space (as shown in the below image). Therefore, following maintenance it is “good practice” to ensure the fire resistance of walls, floors and ceilings and to safeguard again if necessary.

Meeting minimum fire standards is not enough

Technology must solve industry problems. Not only to become a successful business in terms of profitability but in terms of sustainability and genuinely offering service to the industry in order to reduce risk, improve safety and hopefully have a small part in saving lives. We have provided a smart solution to quick and easy assurance of compartmentation using ultrasound to detect signal leaking through any apertures within the barriers.

Ultrasonic room integrity testers provide interpretation of the fire resistance of the desired locations, labelling them either airtight or giving an indication of the overall leakage of the room. The advantages of being able to accurately detect the exact leak locations and size are self-evident when considered alongside the resistance to collapse and transfer of excessive heat. In a case where there is too much leakage in a room, the ultrasonic room integrity tester is an unrivalled ideal for the rapid and accurate identification of these sites so that they can be sealed. It is lightweight, fast and easy to use, allowing leak site detection to increase its operational efficiency and speed to a degree that has never been seen thus far in the Fire Industry.

The technology exists right now to solve this problem.  

In 2018 with the continuing developments in technology there is an expectation that safety should be all encompassing. We cannot let this expectation continue to be a fantasy.

BOX OUT – Case Study: Oxygen Reduction System - Data Centre, England 2018

Oxygen Reduction System and Need for Monitoring: Oxygen Reduction system works by taking Nitrogen from the air outdoors and pumping this into the room consistently in order to suppress oxygen levels, down to the level where combustion can no longer occur. To ensure the system works safely and efficiently, room integrity is of utmost important for two reasons: (1) A properly sealed room will contain the Nitrogen for a longer period of time, therefore putting less work on the air compressor in order to save energy. (2) If Nitrogen starts to leak from the Server Room, there are safety concerns over where this Nitrogen would leak to as it has the potential to harm occupants in other rooms if the Nitrogen leaks into their room and the oxygen levels were unmonitored.

Testing of the Server Room: The Server Room had an area of about 91 metres square. Several areas were tested with an ultrasonic room integrity tester where leakage was probable and the readings were noted on the drawings. These were the doors, vents, cable penetrations and also sections of the wall where gaps were visible.

Results: The ultrasonic room integrity tester identified the main source of leaks for the room, the doors, where full readings were clearly detected. Multiple air vents in the room were also improperly sealed and some leakage was found into the external room. Cable penetrations leading to the area outside the Server Room were also found to be leaking. 

Conclusions: Once the required maintenance was conducted and assuming no changes were made to the room, it is safe to assume that the room retains its integrity, thus comply and exceed current ISO 14520 regulations requiring periodic inspections of room integrity whereby visual inspection is usually specified and is not sufficient. The most suitable way to address periodic inspections is through the use of ultrasound.

Maintain Seal Integrity

Ultrasonic Technology is being rapidly adopted as a safe, easy and accurate method of identifying seal leak sites and has been quickly adopted by the Royal Navy to quickly identify any incorrectly installed MCT's. UT equipment has now been in service for 3 years aboard HMS Albion and HMS Bulwark, and has also recently been adopted this year by the Indian Navy, and Indian Coast Guard.  

Different models of equipment vary, but in general UT equipment consists of two main units; a generator and a receiver. The generator produces an ultrasonic modulated tone, usually at a round 40kHz which is positioned on one side of the seal. The receiver is then used by the operator from the far side of the closed seal. If at any point the seal is imperfect, the ultrasonic signal will be able to pass though the seal through the leak, which can then be detected by the receiver. Some models of ultrasonic watertight integrity tester are capable of detecting leak apertures as small as 0.06±0.02mm in size. UT testing seals can provide the sensitivity to detect the smallest leaks, and can give two different types of readout scale: linear and decibel. The linear scale provides an intuitive measurement of the leak size, whereas the decibel scale allows for comparison of standards set by international classification societies. Use of UT is far more efficient that the methods described above, taking less time, requiring no clean up and is used in a portable, light-weight model for ease of use. Due to its convenience, UT tests can be conducted more frequently and can contribute to safety management and preventative maintenance procedures on board. Moreover, the accuracy of this method is unrivalled, and leak sites can be identified and specifically located quickly for the operator. Furthermore, ultrasonic level indicators use safe and green technology; it that does not violate any environmental codes, which also means there are no IATA transportation restrictions.

Weather, water and airtight seal integrity has be shown to be of vital importance to the crew of all marine vessels, but they play an especially significant role for warships that are subject to especially harsh and sensitive conditions. The importance of continually maintaining seal integrity has been extremely undervalued, and should take a more prominent position in ship maintenance scheduling. Traditional means of integrity testing has been exposed as insufficient and ineffective, putting crew members and marine operational activities at risk. Ultrasonic Technology has been proven as the most practical and accurate form of leak site detection and seal testing, and equipment such as Portascanner® II can alert crew to failing seals early. Coltraco is constantly pushing the boundaries of scientific research to ensure the safety of operators around the world, and is developing continuous and automatic UT testing for real time ship analysis.

How does the use of ultrasonic solutions compare to use of traditional systems in the ferry and cruise market? 

The traditional means of testing CO2 cylinders is to shut-down, dismantle, weigh and re-install them –a time consuming and dangerous task. It takes a 2-man team a minimum of 15 minutes to do this. A ship may have 600 cylinders.

 Using Portalevel™ means a service technician can test for cylinder contents in 15 seconds per cylinder whilst the cylinder stays in position.

 Addressing these two main causes of vessel loss are critical, especially when all owners and managers are seeking to reduce risk, cut costs and surge on safety. 

 Coltraco Ultrasonics also won the Seatrade Cruise Award “Supplier of the Year 2017” for their supply of the Portalevel® MAX Marine to Carnival Cruises. Carnival Cruises chose to protect their fleet by improving fire safety. Using ultrasonic technology - to pinpoint the ultrasonic liquid level indicator of suppressant agent in the cylinders of the extinguishing system- testing is quicker and easier. Portalevel® MAX Marine enables its users to go above and beyond minimal regulations compliance e.g. IMO SOLAS FSS Code.

What is the Safeship concept?

In short, delivering the Safeship® is Coltraco Ultrasonics’ commitment to our mission of improving safety of life, asset and infrastructure at sea.
 Coltraco Ultrasonics implemented the Safeship® concept, to promote protecting critical infrastructure at sea. Bad industry practice is unacceptable when fire risk may have catastrophic results due to risk to life, downtime in operation due to shipsafety and repair work and incalculable reputational damage. The crew, cargo and vessel must be protected when at sea because it is it’s own fire brigade without accessibility to typical emergency services. This is a call to respond to regulations with a rigorous attitude, to go above and beyond, to provide security of life and infrastructure.

 The Safeship® has been nominated as the Safety Initiative of the Year 2018 by Seatrade Maritime Asia Awards. 

 As a result, Coltraco designed the FLEETSAFE: a package of innovative safety tools to combat the above and comply with regulations

  • An ultrasonic watertight integrity tester
  • An ultrasonic thickness gauge
  • A bearing indicator
  • An ultrasonic liquid level indicator
  • A calculator which converts liquid level readings to weight.

With this package the hatch-covers, doors, MCTs, compartments, pipework, hulls, bulkheads, rotating machinery, pumps, sprinkler systems and gaseous extinguishing installations are protected. The package is based on integrity, from design, through to life-time support, and is accurate, reliable and easy to use for any crew members.

The Award Winning Portasteele® CALCULATOR:

Traditionally cylinders are manually weighed by turning off and dismantling each one, which may be risky and takes on average two people 15 minutes per cylinder.
To solve this problem, Coltraco Ultrasonics developed the innovative 8th generation Portalevel® MAX:  handheld ultrasonic liquid level indicator to inspect CO2, clean agents and more liquefied gaseous agents, by one person in just 30 seconds. Combined with the Portasteele® CALCULATOR these liquid level heights are converted into the weight of agent. This tablet based advanced calculator application is the first in the world to provide agent weight readings without physically weighing the cylinders to comply with regulations.

It is the first liquid level indication method to take account of the temperature affect on the agent height. Portasteele® CALCULATOR provides instant real-time results which can be recorded then emailed directly for datalogged audit trail. By replacing the use of manual calculation and formulae, Portasteele® CALCULATOR makes the whole process of fire suppression system servicing simple and effective.
This is a safer, more efficient and cost saving method to service fire cylinders. The technological innovation ensures an entirely user friendly and industry leading device.

What is the Portalevel® MAX NIPPON?

  • Fast Operation
  • Three Years Warranty
  • Lifetime Support
  • Class Approved
  • Ultrasonic clean innovation
  • Not radiation
  • Specially intended for Japanese Market
  • Measures multibank columns 2-3 profound
  • Service a chamber in less than 30 seconds

Specialized Specifications of Portalevel Max Nippon: Here, we have enrolled specialized specs accessible with this ultrasonic liquid level indicator. Give it a look!

Measurements:

  • Height: 160mm
  • Width: 82mm
  • Weight: 300grams
  • Depth: 30mm

Undeniable Agents:

CO2, H20, FM-200™, NOVEC™1230, old Halons, for example, 1301 and 1211, FE-13™, FE-25™, FE-36™, HFC-225 and 2271

Precision:

+/ - 1.5mm (1/8 inch)

Sensors:

TX/RX Dry Sensor:

  • 14 mm distance across head
  • Contained inside a charged sensor implement
  • Connected by BNC connectors to 1 m length co-hatchet link.

Smaller than normal Extension Rod Sensor:

  • 1 meter long
  • 14mm in distance across
  • Connected by bnC connectors to 1 m length co-hatchet link.

Display:

Layer control worked, LCD illuminated Display estimating 55 x 28 mm

Power Supply:

4 x AA 1.5V Batteries (battery life 10 hours)

Working Temperature:

  • 20°C to +70°C (68°F to 158°F)
  • Relative Humidity - 5 % - 95 %

Declarations:

  • Classification Society Approved-RINA
  • CE
  • ISO 19011 Registered

Order:

  • IP Rating 65
  • NATO Stock Number: 6680-99-275-5292

Guarantee:

  • Main Unit: 3 Years Warranty
  • Sensor: 1 Year Warranty
  • Lifetime Customer Support

Portalevel Content:

  • Portalevel® MAX Nippon unit
  • 1 Wet Sensor
  • 1 14 mm Extension Rod
  • Ultrasonic Gel
  • 1 Hard Wearing Carrying Case
  • Calibration declaration

Examples: Fire at Sea

There are numerous example of fire at sea, with just a few included below:

(a) MSC Flaminia, 2012

In July 2012, the container ship was exposed to an uncontrollable fire which tragically lead to three fatalities and two severely injured crew members, as well as dire damage to the ship structure and its cargo. In this example, the actuation of the CO2 and Marine CO2 Systems failed when it actuated without instruction in the engine room, although the discharge was intended for cargo hold 4, which turned off the auxiliary boiler and auxiliary fan for the main engine. This led to an out of control fire which required three salvage tugs to deal with the effects of the explosions and fire. However, the extent of the fire meant that the salvage teams could not enter the vessel for 4 days. Cargo areas 3-7 in the ship were significantly damaged and the ships structure was weakened, requiring replacement. Under the pressures, the hatch covers lost their integrity and bulkheads were severely damaged which led to water ingress in all the cargo. The ruling from this event has stated that $280 million of liability will be shared as a result of the incident .

2.4 (b) Barzan, 2015

On September 2015, a fire was detected inside one of the cargo holds of Barzan, a Maltese registered container ship. The fixed CO2 system was used but due to a number of leaks in the CO2 line, the required amount of gas did not reach the cargo hold to be effective to smother the fire. The starboard fire main line then developed a large leak at a joint in the under deck passage way and had to be isolated. This restricted the fire-fighting efforts to only the port side, and rendered the starboard side water drenching system unusable. The safety investigation concluded that although the CO2 system and fire mains had been tested satisfactorily prior to the vessel’s delivery in May 2015, the quality of the workmanship had contributed to the subsequent failure of both systems .

2.4 (c) CCNI Arauco, 2016

A major fire broke out in an after hold of the container ship CCNI Arauco at Hamburg’s Burchardkai terminal in September 2016. A fire department spokesman said that over 100 emergency services personnel, four fire engines and two fire boats were on site to fight the blaze on the day of the incident. Early efforts focused on cooling the hull to prevent structural damage. An initial attempt to smother the fire with CO2 was not effective, and firefighting operations continued through night. The depth of the fire’s location within the hold added complexity to the response. Repeated CO2 discharges from the ship's own fixed firefighting system were not sufficient to halt the blaze in the Arauco's hold, and a major shore-based intervention was required instead . 
In each of these examples, the actuation of the CO2 and Marine CO2 Systems failed to control the fires on the vessels, some with devastating results. If gaseous extinguishing systems were at their full concentration at all times, then in the event of a fire, they would be able to extinguish the fire which quite clearly above, they were not able to. In every fire marine accident report they nearly always say the CO2 discharged on actuation. If it did the fire should have been extinguished.

Why is fire safety still being ignored

The UK P&I Club have suggested that extended periods of time on board a ship without a fire incident can lead to complacency and therefore a failure of prioritizing prevention methods and fire incident practices. It is impossible to prepare for all eventualities on a vessel, and it is often easier to influence the prompt detection of fires and their effective extinguishment, and these factors therefore play a key role in minimizing fire damage aboard vessels.

The Ungoverned Space is the area where either the regulations or the protecting systems of the tankers are not effectively providing consistent and reliable safety. This life-threatening issue must be dealt with, with specific regard to loss of contents in fixed fire extinguishing systems and need for improvements to room integrity testing. Even in 2017, gaseous fixed fire extinguishing systems are often overlooked, and are misunderstood at all levels: owners, managers, chief engineers and crew.

Look after your installations or pay the price of fire

Tankers extinguishing installations are its essential defense against the risk of fire at sea. The main factor that needs to be understood is that they must be able to actuate, or release their gas, in the event of a fire. Gaseous extinguishing systems are highly pressurized, the risk of leaking and discharging is accepted as part of their use, shown in the regulations that demand their upkeep e.g. IMO SOLAS FSS Ch5. 2.1.1.3:

“Means shall be provided for the crew to safely check the quantity of the fire extinguishing medium in the container”
Adding to this, the details of their leakage within the regulations which is troubling. ISO 14520-1 clearly states that:

If a container shows a loss of agent quantity or a loss of pressure (adjusted for temperature) of more than 5 %, it shall be refilled or replaced

Given that the gaseous systems are designed specifically to the individual need of the tanker then a 5% loss of agent may mean that they would not fully extinguish the fire. Manual weighing is not only laborious, but also dangerous to the crew conducting the servicing.

Innovative Solutions

  • Portalevel® MAX Marine is designed primarily for the vessels’ crew to inspect large fire suppression systems of up to 600 cylinders.
  • The ease of operation in comparison to weighing, increases the ability of more regular and frequent checks, improving fire safety management onboard.
  • Coltraco’s innovative method of inspecting leaking cylinders with ultrasonics, enables identification in under 30 seconds using Portalevel® with one person, instead of the traditional 15 minutes, with two people laboriously weighing.

The Portasteele® Calculator is an advanced calculator application, that converts the liquid level indicator height of C02, NOVEC™ 1230 and FM-200® liquefied gaseous extinguishant agent readings taken on an ultrasonic non-destructive liquid level indicator device into the agent weight/mass.  Furthermore, the Portasteele® can convert an expected agent weight back to the required liquid level allowing users to anticipate where the level should be. The Portasteele has widely been recognised by awards, as a finalist in the Safety at Sea Awards 2017 and the Tanker & Trade Awards 2016.

Addressing fire at sea is critical, especially when all owners and managers are seeking to reduce risk, cut costs and surge on safety. Owners and managers, to servicing companies and insurers - use Coltraco Ultrasonics.

Constant Monitoring of Gaseous Extinguishing Systems

A data center is expensive to build and maintain. It generates significant heat. Every bank with a branch network has hundreds of them. The value of them are very high but the value of their inability to sustain business continuity is far higher than their physical assets. Almost incalculable. And yet Insurers are asked to underwrite them and the fire industry to deliver their protection at the cheapest price. Who today in the security industry would consider installing an alarm system without monitoring its status not only its actuation and integrating the whole of it to the building management system with central monitoring being an essential part of it ? Who would build a ship or offshore platform and fit it with say power generating auxiliary machinery without installing emergency power systems or monitoring their condition states? These are basic engineering principles.

All good engineering demands the monitoring of dynamic structures and a highly pressurized cylinder is a dynamic structure. It is designed to protect a critical infrastructure or asset. Without constant monitoring a risk is generated in the very environment for which it is designed to reduce risk. The risk is not only to the asset, but to the people who work in the asset and their ability to enable business continuity in the high value asset under risk. We aim to be the lead technical authority in the constant monitoring of gaseous extinguishing systems during the life of the system once it is installed and commissioned.

Why is an ultrasonic solution better than a tradition technique and why does it increase the likelihood of tests being carried out? 

In short, the Portalevel® MAX ultrasonic liquid level indicator enables one person to test the contents of a cylinder in 30 seconds, compared to traditional manual weighing with two people to test the cylinder contents in 15 minutes. Ultrasonics is better, faster and cheaper – therefore increases safety because the crew are more likely to be happy conducting the tests more frequently.

 Gaseous extinguishing systems are highly pressurised, the risk of leaking and discharging is accepted as part of their use, shown in the regulations that demand their upkeep e.g. IMO SOLAS FSS Ch5. 2.1.1.3:

 “Means shall be provided for the crew to safely check the quantity of the fire extinguishing medium in the container”

 Often this is misunderstood, this code specifically states that thecrew must test their extinguishing installations in between the periodic inspection, maintenance and certification. Only having the annual inspection by accredited marine servicing companies is not enough – the crew must take responsibility for its own fire protection.  However, what must be noted is that the crew are often not trained or certified to shut-down, dismantle, weigh and re-install the gaseous cylinders – the traditional method.

 Coltraco Ultrasonics focus on benefitting the crew; designing innovative ultrasonic solutions which promote safety culture, which the crew will be happy to use by being easy to operate, quick, accurate and a better method to traditional techniques.

 The Portalevel ® MAX Marine is designed primarily for the vessels’ crew to themselves inspect large fire suppression systems of up to 600 cylinders. The ease of operation in comparison to weighing, increases the ability of more regular and frequent checks, improving fire safety management onboard. Coltraco’s innovative method of inspecting leaking cylinders with ultrasonics, enables identification in under 30 seconds using Portalevel® with one person, instead of the traditional 15 minutes, with two people laboriously weighing.

 This can be in-between the statutory annual maintenance and certification intervals provided by shore-based contractors. Thus, increasing the likelihood of tests being regularly conducted, in line with regulations and even going above and beyond for more frequent testing. By so doing, the crew will be creating a safer ship. 

The Swedish P& I club recommend using Ultrasound.

As stated in their 2018 report “A much more effective method is to use an ultrasonic device, which is designed for this purpose and can pinpoint the area which is leaking, and if the compression of the gasket is sufficient. The advantages of using this type of equipment are evident, since ultrasonic tests can be carried out during any stage of the loading without risking cargo damage. The test can also be completed in sub-zero temperatures. The ultrasonic test should be carried out as per the class requirements.” 

 Ultrasonics is proven to be the quickest, easiest and most efficient method of testing watertight & weather-tight seals of hatch-cover tester, doors, multiple cable transits. The Portascanner® WATERTIGHT is the most accurate model of its kind – proven to 0.06mm (+/-0.02mm). This is designed primarily to enhance the ease and accuracy with which critical watertight, airtight or weather tight seals can be inspected for leak sites or areas of reduced compression in the seal. The ultrasound generator emits a modulated signal of a specific frequency of ultrasound (in most cases 40,000Hz). The receiver then picks up the signal and converts it into a result indicating watertight integrity. The easy to use Portascanner® WATERTIGHT allows crew member to check for failing seals whilst at sea which allows for prompt maintenance.  

 Coltraco Ultrasonics focus on benefitting the crew; designing innovative ultrasonic solutions which the crew will be happy to use by being easy to operate, quick, accurate and a better method to traditional techniques. Thus increasing the likelihood of tests being regularly conducted, in line with regulations and even going above and beyond for more frequent testing. By so doing, the crew will be creating a safer ship.

The Fleetsafe® Package

Gaseous extinguishing systems are highly pressurised, the risk of leaking and discharging is accepted as part of their use, shown in the regulations that demand their upkeep e.g. IMO SOLAS FSS Ch5. 2.1.1.3:

“Means shall be provided for the crew to safely check the quantity of the fire extinguishing medium in the container”

Often this is misunderstood, this code specifically states that the crew must test their extinguishing installations in between the periodic inspection, maintenance and certification. Only having the annual inspection by accredited marine servicing companies is not enough – the crew must take responsibility for its own fire protection.  However, what must be noted is that the crew are often not trained or certified to shut-down, dismantle, weigh and re-install the gaseous cylinders – the traditional method.

Coltraco Ultrasonics focus on benefitting the crew; designing innovative ultrasonic solutions which promote safety culture, which the crew will be happy to use by being easy to operate, quick, accurate and a better method to traditional techniques.

The Portalevel ® MAX Marine is designed primarily for the vessels’ crew to themselves inspect large fire suppression systems of up to 600 cylinders. The ease of operation in comparison to weighing, increases the ability of more regular and frequent checks, improving fire safety management onboard. Coltraco’s innovative method of inspecting leaking cylinders with ultrasonics, enables identification in under 30 seconds using Portalevel® with one person, instead of the traditional 15 minutes, with two people laboriously weighing.

This can be in-between the statutory annual maintenance and certification intervals provided by shore-based contractors. Thus, increasing the likelihood of tests being regularly conducted, in line with regulations and even going above and beyond for more frequent testing. By so doing, the crew will be creating a safer ship.

Coltraco Ultrasonics implemented the Safeship® concept, to promote protecting critical infrastructure at sea. Bad industry practice is unacceptable when fire risk may have catastrophic results due to risk to life, downtime in operation due to ship safety and repair work and incalculable reputational damage. The crew, cargo and vessel must be protected when at sea because it is it’s own fire brigade without accessibility to typical emergency services. This is a call to respond to regulations with a rigorous attitude, to go above and beyond, to provide security of life and infrastructure.

As a result, Coltraco designed the FLEETSAFE: a package of innovative safety tools to combat the above and comply with regulations

  • An ultrasonic watertight integrity tester
  • An ultrasonic thickness gauge
  • A bearing indicator
  • An ultrasonic liquid level indicator
  • A calculator which converts liquid level readings to weight.

With this package the hatch-covers, doors, MCTs, compartments, pipework, hulls, bulkheads, rotating machinery, pumps, sprinkler systems and gaseous extinguishing installations are protected. The package is based on integrity, from design, through to life-time support, and is accurate, reliable and easy to use for any crew members.

Wind turbines require an active fire protection system

It is estimated that 0.3-0.5 fire incidents occur per 1000 wind power stations (onshore and offshore) every year (Technical Research Institute of Sweden). 10-30% of all loss-of-power-generation incidents in wind power plants are due to fire.

Potential ignition sources are mainly inside the nacelle where there is fast moving machinery (generators, gearboxes e.t.c) which creates heat and combustible oil and solid material in the. Even with the incredible engineering and safety measures in place, a fire can ignite and develop, leading to the possible complete destruction of the turbine.

Wind turbines require an active fire protection system, which includes but is not limited to detection (of flames, heat, gas, and smoke), alerting personnel and rescue services, and activating systems for fire suppression or extinguishing. Due to the height and location of wind turbines, classic firefighting methods come up against their limits and therefore fire extinguishing systems that use gases such as carbon dioxide, inert gases or clean agents such as FM-200® and Novec 1230 gas suppression system, which are especially appropriate for dealing with fires in electrical systems because they extinguish the fire quickly whilst not damaging the electrical systems or the compartment in which they are being discharged.

Regulations demand maintenance of the systems to ensure that they are operational in the event of a fire: ISO 14520-1:2015(E) assumes that these systems accidentally discharge and leak. 9.2.1.3 The storage container contents shall be checked at least every six months as follows. a) Liquefied gases: for halocarbon agents, if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure (adjusted for temperature) of more than 10 %, it shall be refilled or replaced.”

The reality is that gaseous systems are checked for contents annually because they are pressurised and anything that is dynamic offers risk of loss of contents, but this fails to deal with the probability of discharge or leakage for the 364 days per annum in the interim between certification checks.

Coltraco have now developed the Permalevel® Multiplex, a fixed fire suppression monitoring system, designed for continuous contents verification. Permalevel® is designed to ensure that FM 200 fire suppression system are always fully operational and that no accidental discharge has occurred, which could affect the effectiveness of the overall fire protection system in the event of a fire.

Watch our YouTube Video to show how the Portalevel® MAX works

https://www.youtube.com/watch?v=8XaG7oM5aHA&t=48s

  1. Place the sensor on the cylinder & press ‘CAL’. This sets the unit up on each cylinder.
  2. The bar will go to 100%. Full bar graph indicates gas, no bar graph indicates liquid
  3. Move the sensor down the cylinder in small steps
  4. Look at the graph. When it disappears, you have reached liquid. 

For regular inspection, the Portalevel® MAX is a handheld ultrasonic liquid level indicator, which can service a cylinder in 30 seconds (in contrast to 15 minutes by traditional manual weighing) with accuracy of up to 1.5mm off the true liquid level. Portalevel® MAX builds on Coltraco Ultrasonics’ 30 years’ experience in designing, manufacturing and supporting ultrasonic liquid level indicating equipment, in 108 Countries and numerous market sectors and environments. The development program was born out of the desire to further improve on Coltraco’s existing 8 designs and taking on board feedback and opinions of our customers.

Implement Constant Monitoring

Gaseous extinguishing/suppression systems are installed to protect against special hazards in critical infrastructure as their key objective. They deliver the infrastructural resilience our advanced society requires. If the hazard is special and the infrastructure critical, then this is the case for the constant monitoring of the suppression systems that aim to deliver their protection.

The assumptions in the installation, commissioning and maintenance of gaseous extinguishing systems is that they are highly pressurised but risk leaking and discharging. The regulations that sensibly underpin this assumption aim to identify their leak identification at an interval of every 6 months. A cup of water stands at 1bar pressure – approximately 14.5 psi. Gaseous systems vary in pressure from FM-200® or NOVEC™ 1230 at 25-30 bar, CO2 at 50 bar or 720 psi to Inergen at 300 bar or 4,500 psi. These are very highly pressurised systems. In engineering terms, they are “dynamic” systems, not passive ones.

So why then does the fire industry not constantly monitor them?

The core regulation enshrined in BS EN ISO 14520 -1:2015(E) and we should be proud it exists. But let us examine what it says.

BS EN ISO 14520 -1:2015(E) reasonably assumes that the execution of its provisions is entrusted to people qualified and experienced in the specification, design, installation, commissioning, testing, approval, inspection, operation and maintenance of systems and equipment, and who can be expected to exercise a duty of care to avoid unnecessary release of extinguishant. Attention is drawn to the Montreal Protocol on substances that deplete the ozone layer. It is important that the fire protection of a building or plant or any other critical infrastructure be considered as a whole. Gaseous extinguishant systems form a part of the available facilities, but it should not be assumed that their adoption necessarily removes the need to consider supplementary measures, such as the provision of portable fire extinguishers or other mobile appliances for first aid or emergency use, access by a Fire Rescue Service or any other measures that can be applied as part of a wider fire protection plan.

Gaseous fire systems deliver the very resilience we need. But resilience means the permanence of capability and functionality. That permanence can only be delivered by constant monitoring of the systems that enable it.

The science of a gaseous extinguishing system is a complex one. The mathematics that underpin its science are demanding ones. But in simple terms gaseous systems are pressurised and in that they are dynamic not passive ones. They are there to protect critical infrastructure in a a safe and expeditious manner in the only way that a gaseous system can. We would not imagine an alarm system exists without monitoring it 24/7, but why are we still leaving unattended the very automatic gaseous clean agent extinguishing systems that protect us when even the core regulations of its installation and maintenance specifically allude to its potential to accidentally discharge or leak its contents ?

Fortunately lead elements of the critical infrastructure community are asking the same question. So are the world’s insurance companies.

But should our own fire industry not answer the question by implementing constant monitoring 24/7/365 before it is asked of them by the very people it is helping protect ?

Where can the Portascanner® WATERTIGHT be used?

Portascanner Watertight is a portable Ultrasonic Hatch Cover Tester and Watertight Integrity Indicator for testing watertight and weather-tight seals. It is ideal for checking the hatch-covers, doors, cable transit areas, scuttles, flanges, shell doors, steering gear hatches and others. Coltraco has designed this product to enhance the ease and accuracy with which critical watertight, weather tight and airtight seals can be inspected for leak sites or areas of reduced compression in the seal.

Application Hatch Cover Tester

Ultrasonic hatch cover tester is best for the following applications:

Bulk Carrier Hatches

The Portascanner® Watertight is used onboard bulk carriers for inspecting the Watertight or Weather-tight hatches for leak sites. The magnetic generator can be positioned just inside the hold, on the hatch combing, removing the need to climb down to position the generator at the bottom of the hold on the tank top.
It is used by the crew for regular maintenance to dramatically reduce the risk of cargo damage from water ingress, and by Marine surveyors for carrying out P&I, Classification Society or Insurance surveys.

Watertight Doors

Watertight Doors on offshore Oil & Gas Rigs, Naval and Marine Vessels are regularly inspected & maintained to ensure the integrity of the Bulkheads and watertight barriers are secure. If these areas are neglected, there can be drastic impacts on flood prevention in the event of a major incident, which is exactly what the Portascanner helps to avoid. Removing old fashioned and inaccurate chalk testing, the Portascanner Technology provides a very quick and accurate method to identify problem areas and fix the issues that exist within these seals.

Multiple Cable Transits (MCTs)

Cable Transit Seals provide a key element in maintaining the integrity of bulkheads and watertight seals onboard Naval, Offshore Oil & Gas and Marine assets. Portascanner being a multiple cable transit areas testing device is efficient in checking the condition of this main element. As one of the most neglected areas onboard, having the means to quickly identify the exact location and severity of issues in MCTs can dramatically assist Contractors and Fleet Operators to enhance the flood, fire & smoke protection that a correctly installed MCT seal provides.

For further information and inquiries, leave a message for Coltraco Customer Service.

Improve Safety Management Systems with the Portasteele® CALCULATOR

A key elements of the offshore protective system is the fixed fire suppression system. These are made up of a number of cylinder points that will release the suppressant agent when a fire incident is detected.  One of the key challenges with fixed fire suppression systems has been monitoring the individual cylinder points liquid level. Cylinder points can suffer from leakage and accidental discharge over time. Often, cheap systems only minimally comply with the regulations and there are very few qualified engineers who may be considered experts on the subject matter. Routine maintenance is liable to be overlooked because it is difficult, the crew are unqualified to test and may be given insufficient attention by the rig owners. No longer necessary to use the laborious weighing method to monitor the contents of suppressant agents, now ultrasonic technology offers a better method. The Portasteele® Calculator is an advanced calculator application, that converts the liquid level height of C02, NOVEC™ 1230 and FM-200® liquefied gaseous extinguishant agent readings taken on an ultrasonic non-destructive liquid level indicator device into the agent weight/mass. The cylinder database function means often tested cylinder types, such as 45kg CO2, commonly found on supply vessels, rigs and platforms, can be recalled reducing testing time, providing an incredibly quick to use tool. Plans to incorporate additional functionalities, such as agent type indication, are already in their final planning stages. In the long term, the acquisition of Portasteele® Calculator into offshore platforms, oil tankers etc. will improve overall Safety Management Systems and reduce cost associated with the maintenance of fire suppression systems. When these fire systems are properly maintained, the cost associated with fire damage is likely to reduce dramatically as we know fire damages on these hazardous offshore environments are generally catastrophic to lives, asset, environment and company reputation.

Fire Safety Onboard

In terms of ships’ extinguishing systems there exist two broad categories: sprinkler systems and gas systems (CO2). While the former can suffer leakage but the latter can cause catastrophic effect given the high physical pressures. An average ship’s CO2 system comprises between 200 and 600 cylinders each containing 45KG of CO2 under high 720 psi/ 49 bar pressure. One of the highest probabilities of discharge occurs during their maintenance. Some marine service companies estimate that 20% of a ship’s CO2 cylinders have discharged or partially leaked their contents at some point in their lifetime.

Although random checks may be suitable in some sectors, it is worth remembering that because the normal design concentration of CO2 of 34-72-v/v % is above the nearly immediate acute lethality level, these systems have an extremely narrow safety margin. As these systems work through oxygen dilution rather than the chemical disruption of the catalytic combustion chain (which is the case with other clean agents), insufficient CO2 levels during an emergency may allow a situation to spiral out of hand. Gaseous extinguishing systems protect urgently important infrastructure against special hazards, fundamental for the safeguarding of critical facilities. Yet, because gaseous extinguishing systems are highly pressurized, the risk of leaking and discharging is accepted as part of their use and this is shown in the regulations that demand their upkeep so it is always recommended to possess ultrasonic level indicator onboard.

Moreover, with fewer, even lower-skilled crew and greater dependence on autonomous machinery, the dependence on fire systems being checked from shore, let alone on the ship in person, will only become greater. Manual weighing is not only laborious, but also dangerous to the crew conducting the servicing. Numerous accounts of incidents have been reported related to manual weighing, but two of the most significant are the injury to 22 US Marines when a Halon-containing fire extinguisher went off in 2015, California and the death of 20 people in an accident on a Russian nuclear submarine when a Halon extinguishing system was activated by mistake.

Without the means to manually check and with the threat to the crew, constant and remote monitoring becomes vital. It can be argued that the existence of regulation (such as that set by the IMO and other authorities) guides – and occasionally curbs – the direction taken by the free market. This then means that the current state of the market, where ‘price is king’ is either due to unwillingness on the part of the regulators to create an environment where safe engineering is rewarded or because the industry itself is unaware of new technology that will help them meet both the spirit and letter of the regulation.

Cost Cutting, Lack of Experience and Increasing Risks

Although the value of the marine assets that fire systems protect is increasing rapidly, the competitiveness of the free market places great pressure on cost cutting. Often, cheap systems only minimally comply with the regulations and, in fact, there are very few qualified engineers who may be considered experts on the subject matter. This creates an environment in which a ‘safety first’ culture remains both un-pursued and unrewarded.

Routine maintenance is liable to be overlooked because it is difficult and the crew unqualified to test or given insufficient attention by the owner of the system. The neglect of continuous monitoring of the fundamental protection provided by the gaseous extinguishing systems is to the peril of the lives of occupants of the ship and at the risk of crippling financial and reputational loss to the tanker owner. It is usually the case of systems like these that they are out of sight and out of mind, and they are often located in some plant room, which only the maintenance contractor visits, if at all. The most modern technology is integration of ultrasonic technology in monitoring devices.

Operating Method of Ultrasonic Technology

Sound is, in itself, vibrations that propagate as a mechanical wave or pressure and transmit through solid, liquid or gaseous mediums. Coltraco is one out of a number of companies using these fundamental physical principles to design and manufacture products and systems that can be used by fire engineers and their customer installations. It has a huge range of products, which are all integrated with ultrasonic technology such as ultrasonic liquid gas level indicator. Ultrasound is merely sound beyond our audible range. Dolphins and whales can communicate at sea over long ranges as sound travels more efficiently through liquids than air. We use this principle to identify that difference in a cylinder containing liquefied agent. Consider one’s ears as “the receiver” and one’s mouth as the “transmitter”. Sound will arrive at the ears at different times. The reason though that we hear a unitary sound is that our brain processes it to one. This is what we do by processing the returning ultrasound. In the air bats navigate by airborne ultrasound. We can do the same for contents and room integrity monitoring in the fire industry.
In terms of contents monitoring of single walled fire suppression cylinders in the fire industry, a sensor is utilized as a transceiver to transmit ultrasonic pulse through the walls of the cylinder and to analyze the strength of the returned signal that determines the level of contents. As sound behaves differently in air and liquid, so will the strength of the returned signal be different in the liquid and air allowing us to identify the level of contents accurately.
To make any inquiry, please contact Coltraco Customer Service.

Gas systems leak - it's official! The need for improving safety by continious monitoring

Too often in the fire industry it feels like the certification is driving the maintenance, with its insurance consequence for the asset owner and service revenue for the contractor, rather than maintenance [for safety sake] driving its consequential certification. The ‘ungoverned space’ is the area in the fire industry where either the regulations or the protecting systems of the critical infrastructure are not effectively providing consistent and reliable safety.

People expect, and rightfully so, that in the event of a fire the extinguishing systems would be in full working order to do just that – extinguish. Given that the gaseous systems are designed specifically to the individual need of that room, building e.t.c, then a leak sites in the room could meant that the comparted area couldn’t withhold the fire. The likelihood of the gaseous system effectively extinguishing the fire gets lower and lower as the protected area becomes larger than the size that the extinguishing system was designed for. This is not a game of chance. The lives of people depend upon it.

Although many in the fire industry work towards meeting better standards, in their experience, Coltraco have numerous concerning anecdotes of non-compliance: systems portrayed and installed by contractors as Novec 1230 gas suppression system but filled with sand or water… room integrity testing with questionable results and with the room integrity remaining un-monitored after testing.

Gaseous Extinguishing Systems

The regulations are not extensive enough to deal with the risks presented in gaseous systems. In 9.2.1.3 the regulations explains that the storage container contents shall be checked at least every six months as follows. : a) Liquefied gases: for halocarbon agents, if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure (adjusted for temperature) of more than 10 %, it shall be refilled or replaced. b) Non-liquefied gases: for inert gas agents, pressure is an indication of agent quantity. If a container shows a loss of agent quantity or a loss of pressure (adjusted for temperature) of more than 5 %, it shall be refilled or replaced. Essentially, it is known in regulations that the gaseous systems leak and need to be maintained. Given that the gaseous systems are designed specifically to the individual need of that room, building e.t.c, a 5% loss of agent may mean that they would not fully extinguish the fire.

Coltraco have now developed a fixed fire suppression monitoring device, the Permalevel® MULTIPLEX which designed for permanent contents verification. The continuous monitoring system is  designed  to  ensure  that fire  suppression  systems  are  always  fully operational and that no accidental discharge has occurred, which could affect the effectiveness of the overall fire protection system in the event of a fire. The neglect of continuous monitoring - of the fundamental protection provided by the gaseous extinguishing systems - is to the peril of the lives of occupants of the premises and at the risk of crippling financial and reputational loss to the facility comprising the critical infrastructure.

The device uses the Internet of Things (IoT). IoT enables a worldwide transmission of data starting from sensor to sensor to the microprocessors and to the facilities manager or maintenance team. Instead of waiting for annual checks, it would improve safety to have these cylinders constantly monitored using ultrasonic sensors. Now, by coupling with IoT developments, this enable their status to be visible to safety managers and building owners.

Figure 1: The Permalevel® Multiplex which uses the Internet of Things to transmit data about the liquid level of fire suppression cylinders continuously

Complement Door Fan Testing: Portascanner® 520

After years of utilizing ultrasonic technology to identify leak sites in marine applications to test for watertight integrity, Coltraco Ultrasonics realised the potential of harnessing ultrasonics to complement door fan testing with leak detection. The unit allows for easy and simple room integrity testing, which can be completed quickly by one person, without disrupting the building occupants. Clean agents are designed to operate in limited spaces where there is a need for speed of suppression given the asset risk and where the space is occupied by people. They must comply with NFPA 2001 and ISO 14520 standards demanding fast discharge in 10 seconds and fire extinguishing within 30 seconds, delivering confidence to the operator that it delivers “best fire safety practise”. As buildings age or their internal use is changed leak sites develop. It is perfectly positioned to work alongside Door Fan testing in order to meet the total requirements for fire safety regulations and ensure the continuous fire protection of rooms using Clean Agent Fire Suppression systems. As Door Fan Testing has been proven to be a trusted method of room testing by industry experts, it is expected that its dominance shall continue in the near future. The immediate use of the Portascanner™ lies in its improvement of the final stage of room integrity testing – the search for leak sites in the case of a leakage excess – for which it can vastly improve accuracy and operational efficiency

The Portascanner 520 is the most accurate unit of its type, locating a leak site via visual ad audible readings and suppling a definitive numerical results. The unit can test leaks as small as 0.06mm, which is unparalleled accuracy compared to the puffer test technology which is a purely visual inspection. The smoke puffer tests also involves evacuating a building or room whereas the Portascanner™ 520 is completely clean and damage free. The advantages of being able to accurately detect the exact leak locations and size are self-evident when considered alongside the importance of reaching Peak Pressure for clean agent fire suppression to be effective. In a case where there is too much leakage in a room (and thus insufficient Hold Time), the Portascanner™ is an unrivalled ideal for the rapid and accurate identification of these sites so that they can be sealed. It is the first of its kind, intuitive to use, non-invasive, and consequently, is of immediate use to the Fire Industry. The unit also has full Classifcation Society Approval with RINA & ABS.

It is lightweight, fast and easy to use, allowing leak site detection to increase its operational efficiency and speed to a degree that has never been seen thus far in the Fire Industry. This method increases safety, by allowing the user unparalleled leak detection. This leads to the user having superior control of the agent hold time and peak pressure, effectively guaranteeing the identification and extent of leak sites. The unit is also lightweight and hand-held, weighing only 419 grams. The unit can also be used as a pre-surveying inspection tool, prior to bringing in full door fan test equipment.

The White Heat of Fire Safety

Aluminium is used in hundreds of industries, especially in the fields of transportation, aerospace, packaging, building and construction. For this reason, the protection of the plants and development facilities is vital, to ensure competitive business continuity. The industry directly creates more than 155,000 jobs and is adding more yearly. With growing numbers of employees in the aluminium industry, their safety and well being has long been a commitment.

There is a need for comprehensive fire safety measures, specifically the fixed fire extinguishing systems in aluminium production and fabrication, in casthouses, foundries, recycling and reclamation plants. When aluminium is burned, it creates a very intense fire. Within the last four months alone there have been several serious fire incidences internationally, at aluminium plants. In Norton Canes, UK in August 2017, there was a serious fire which led to evacuation and over thirty firefighters tackling the blaze. In Wangara, Australia, just last month, there was a huge industrial fire at an aluminium factory, which spread and developed into a wild fire.  The protection of lives and assets against the dangers of fire is a priority for facilities managers and plant owners.

Gaseous extinguishing systems protect urgently important infrastructure against special hazards, fundamental for the safeguarding of critical facilities. However, gaseous extinguishing systems leak because they are active and dynamic systems and this threatens the consistent and reliable safety that they should offer to the space that they protect.

In fact, in the regulation ISO 14520, which is the “gold standard” of fire suppression systems, it is clearly stated that gaseous systems leak and need to be periodically checked to counter this issue:

9.2.1.3  - “if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure of more than 10 %, it shall be refilled or replaced.”

Given that gaseous systems are designed specifically for a protected space or room e.g. one aluminium foundry factory floor, a 5% loss of extinguishing agent may mean that the system would not fully extinguish the fire.

Technology now exists to improve the reliability of fire suppression systems that affects the safety of all who occupies the building it protects in an event of fire.

To  ensure  that fire  suppression  systems  are  always   full and that no accidental discharge or leakage has occurred, Coltraco Ultrasonics have developed an ultrasonic liquid level indicator, the Portalevel® MAX and  the constant monitoring system the Permalevel ® MULTIPLEX. By testing and monitoring fire extinguishing systems for leaking, facilities managers and factory owners are able to exceed  standards and ensure that the gaseous extinguishing systems are able to extinguish in the event of the fire.

The easy to use Portalevel® MAX uses ultrasonic technology to pinpoint the liquid level of suppressant agent in the cylinders of the extinguishing system which makes testing is quicker and easier. Liquid level identification takes just 30 seconds, needing only one person. Combined with the Portalevel® MAX, the Portasteele® CALULATOR is an advanced calculator application, that converts the liquid level height of C02, NOVEC™ 1230 and FM-200® liquefied gaseous extinguishant agent readings taken on an ultrasonic non-destructive liquid level indicator device into the agent weight/mass.  Furthermore, the Portasteele® CALCULATOR can convert an expected agent weight back to the required liquid level allowing users to anticipate where the level should be.

The Permalevel® MULTIPLEX is designed for permanent contents verification.  Using smart ultrasonic technology ,the Permalevel® MULTIPLEX continuously monitors fixed fire extinguishing systems for leaking agents, 24/7, 365 days a year. With guaranteed systems operations, adaptability for purpose, 24/7 remote access to the systems status, an interruptible power supply and remote real-time monitoring, the Permalevel® MULTIPLEX offers the efficiency that is now a requirement for encompassing protection.

Coupled with the danger of leaking agents, room integrity is often an overlooked aspect of a suppression system installation. Room integrity requires that in the event of a fire, the released fire extinguishant must meets the sufficient “Hold Time”, in order to properly extinguish fires. Buildings age and their internal use changes and because of this,  leak sites develop.  The likelihood of the gaseous system effectively extinguishing the fire gets lower and lower as the protected area becomes larger than the size that the extinguishing system was designed for.

Coltraco Ultrasonics have provided a smart solution for quick and easy assurance of compartmentation and leak detection. The Portascanner® 520 ultrasonic leak detector uses ultrasonic technology to not only pinpoint precise leak locations, but to determine their leak size as small as 0.06mm with a tolerance of +/-0.02mm, and is by far the most mathematically proven accurate device for this function.

With the continuing developments in smart ultrasonic technology, comprehensive fire safety measures are available to aluminium plant owners and facilities managers that are easy to use, affordable and an essential addition to any fire safety management system.

Coltraco Ultrasonics is a leading British company operating in 109 countries across multiple market sectors for over 30 years.

Markets Coltraco Ultrasonics Operate In Oil & Gas

We have units in operation on rigs, platforms and offshore support vessels around the globe, notably on approximately 160 of the North Sea rigs overtime, as well as with onshore drilling, exploration and production operations. Portalevel® MAX provides drilling operators, contractors and owners, down to the OIMs and barge managers with the assurance and confidence that their fire suppression systems are operating under an enhanced safety management plan.

Marine

Coltraco’s history is steeped in the Marine sector and Today Ship Owners, Managers and Operators, Port Authorities, P&I Clubs, Towage & Salvage Operators, Shipyards and Service Stations and Marine Surveyors are among our key customers around the world. We have developed products and diversified our range to serve our customers’ needs and Portalevel® MAX is our latest upgrade.

Fire Protection

The Portalevel has been leading in the fire safety and protection sector since we first invented it in 1987 and with the 8th generation model Portalevel MAX, we are pleased to offer an enhanced means of testing and certifying fire suppression systems. This ultrasonic liquid level indicator uses safe and clean technology. Portalevel® MAX aims to reduce time and cost; it is a must-have tool for fire system protection and we have the technical know-how and credentials to verify this

Power Generation

Power plants, transmission sub-stations and distribution networks need to minimize the risks of fire at all costs. For safety critical areas such as nuclear power generation, and the conventional fossil fuel power generation, Portalevel® MAX provides a further means of improving the safety management and preventative maintenance procedures of the fire suppression systems.

Defence

Government organizations and Defense forces around the globe, particularly Naval Forces and Coast Guards, have been using Coltraco equipment for over 20 years. These capabilities are focused upon Safety & Survey applications such as monitoring Naval vessel and Fleet Auxiliary vessel Halon 1301, typically using Portalevel to monitor contents of FM-Halon, FM-200™, CO2 & NOVEC™ 1230 systems.

The Two Principles

If you are an end user, to provide an additional means to check your systems more frequently, outside the regulatory certification checks and enhance your safety management, this ultrasonic level indicator is the best choice.

If you are a servicing company, to conduct certified testing in compliance with regulations, the Portalevel is approved and certified with proven accuracy up to +/-1.5mm and to save 75% of the time to complete testing when compared to weighing cylinders. Moreover, data centres, telecommunications centres, High Rise Buildings, MTR rooms, and others are good for this device to measure the liquid levels.

Please Download PDF for further information or contact Coltraco’s Customer Service, if you want to know if Portalevel® MAX will work with your applications.

3 Reasons Why You Should Monitor Your CO2 systems

Here are 3 reasons why you should monitor your CO2 system:

  • CO2 leaks
  • A fire starts every 7 seconds around the world
  • Insufficient CO2 could mean failure of extinguishment in the event of a fire

How can you protect yourself and your facilities?

Here is a LOW COST constant monitoring device for CO2 & Marine CO2 Systems. It is called Permalevel® LOAD WEIGH. 

Why a Safesite® solution for you:

  • Easier – automatic alarm in the event of CO2 leakage
  • Better – don’t wait for one annual check, monitor 24/7, 265 days a year
  • Cheaper – highly competitive pricing

This is a must have because of this flexibility in the Permalevel® LOAD WEIGH’s applications, from data centres, tall buildings, museums, hotels to industrial sector. 

Discover more today:

How can you ensure the effectiveness of your fire suppression system?

Too often in the fire industry it feels like the certification is driving the maintenance, with its insurance consequence for the asset owner and service revenue for the contractor, rather than maintenance [for safety sake] driving its consequential certification. The ‘ungoverned space’ is the area in the fire industry where either the regulations or the protecting systems of the critical infrastructure are not effectively providing consistent and reliable safety.

The regulations are not extensive enough to deal with the risks presented in gaseous systems. In 9.2.1.3 the regulations explains that the storage container contents shall be checked at least every six months as follows. : a) Liquefied gases: for halocarbon agents, if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure (adjusted for temperature) of more than 10 %, it shall be refilled or replaced. b) Non-liquefied gases: for inert gas agents, pressure is an indication of agent quantity. If a container shows a loss of agent quantity or a loss of pressure (adjusted for temperature) of more than 5 %, it shall be refilled or replaced. Essentially, it is known in regulations that the gaseous systems leak and need to be maintained. Given that the gaseous systems are designed specifically to the individual need of that room, building e.t.c, a 5% loss of agent may mean that they would not fully extinguish the fire.

Coltraco Ultrasonics have now developed a fixed fire suppression monitoring device, the Permalevel® MULTIPLEX ultrasonic level indicator which is designed for permanent contents verification. The continuous monitoring system is  designed  to  ensure  that fire  suppression  systems  are  always  fully operational and that no accidental discharge has occurred, which could affect the effectiveness of the overall fire protection system in the event of a fire. The device uses the Internet of Things (IoT). IoT enables a worldwide transmission of data starting from sensor to sensor to the microprocessors and to the facilities manager or maintenance team. Instead of waiting for annual checks, it would improve safety to have these cylinders constantly monitored using ultrasonic sensors. Now, by coupling with IoT developments, this enable their status to be visible to safety managers and building owners.

The neglect of continuous monitoring - of the fundamental protection provided by the gaseous extinguishing systems - is to the peril of the lives of occupants of the premises and at the risk of crippling financial and reputational loss to the facility comprising the critical infrastructure.

Hatches leak for a variety of reasons, but mainly because of poor maintenance or failure to seal them properly after loading.

 A watertight hatch cover is designed to prevent the passage of water in either direction under a head of water for which the surrounding structure is designed.  Many mariners may think hatches are robust, monolithic structures, thereby failing to appreciate the small tolerances on panel alignment and gasket compression. It is better to think of hatches as complex, finely-made structures, to be handled with care. All types of seals, experience dynamic stresses as part of their operational lifetime. For example, 4mm wear on the steel-to-steel contact is sufficient to damage rubber sealing gaskets beyond repair; 5mm sag along the cross-joint can cause a large gap between the compression bar and gasket.

The risk is worsened by the ageing nature of many bulk carrier ships in particular. There is also a degree of bending/deformation that naturally occurs in ships during travel, which puts pressure on hatch covers and can damage sealing. A recent wave of inexperienced crew members has swept across the shipping industry as a cost-saving mechanism, leaving vessel maintenance and hatch cover testing to decrease in quality. While hatch covers are often perceived as indestructible due to their large size and bulky exterior, in reality they are complex, finely made structures that need to be handled with care, a point that many mariners do not realize.

The case study of the Emma Maersk exemplifies the danger of improper servicing. A severe leakage occurred on the container ship in February 2013 when it was loaded with 14,000 containers. The leakage was caused because of a mechanical break-down of a stern thruster, creating the shaft tunnel to flood, as well as leading to severe ingress of water in the aft part. Eventually there was flooding of the main engine room. This was because of non-effective cable penetration sealing’s, in a sudden blast, four cable penetration sealing’s in the watertight bulkhead gave way to the water pressure followed by a massive ingress of seawater. Shortly after this, the other three cable penetration sealing’s also failed, resulting in an even larger ingress of water into the engine room. This led to approximately USD 45 million worth of damages and towage cost.

The use of UT is far more efficient than the traditional methods described in the previous section, taking less time and requiring no clean up while being in a portable, light-weight model for ease of use. Due to its convenience, UT tests can be conducted more frequently and can contribute to safety management and preventative maintenance procedures on board.

How does ultrasonic technology cut ungoverned space within the fire industry down?

  • Ultrasound is merely acoustic (sound) energy in the form of waves of high frequency that are above the human audible range.
  • Portascanner™ uses ultrasound to test the integrity of confined spaces and can detect leak sites as small as 0.06mm.
  • Portagauge™ uses ultrasound to test the internal and external corrosion on pipework and cylinder wall thickness to an accuracy of +/-0.1mm.
    • Globally we are known for the design and manufacture of 11 different model types of Portalevel™ liquid level indicators.  Accurate to +/-1.5mm for CO2, FM-200™ , NOVEC™ 1230, HFC-225 & 227, remaining Halon systems, FE-13™, FE-25™ and FE-36™.
    •  We can monitor these extinguishing systems 24/7 with the fixed, data-logging and autonomous monitoring system, Permalevel™ Multiplex & Permalevel™ Single Point. Signals from these fixed monitoring sites can be monitored centrally at the customer location and remotely globally.

Smart Solutions

This is the “ungoverned space”; but in it technology offers many solutions. Who today would object to vehicle safety restraint mechanisms? Who today would willingly replace a “chip and pin” credit card with one requiring only a signature? As the world changes, so must our industry integrate technological solutions to provide a bulwark against wider industry misinterpretation and minimal, even occasional and flagrant, disregard in the application of standards and good global engineering practise, creating standards which all can understand and apply.

The “white heat” of technology shines as a beacon of hope to our industry and so too enables justification for customers to actively engage in the monitoring of FM 200 fire suppression system
as an integrated and essential element to their business activity.

Save lives! How & why to improve water mist maintenance.

Despite the difficulty that shipping businesses are subjected to, fire safety standards on board cannot begin to slip. Fires on board ships can be devastating, to crew, vessel and cargo. There is a call to respond to regulations with a rigorous attitude, to go above and beyond, to provide security of life and infrastructure. Water mist FM 200 fire suppression system must be maintained so that they can provide the protection that they are intended for: protecting lives, assets and vessels whilst at sea.

Assessed by FM Global, one of the main causes of failure to water mist systems derives from human error, commonly the water tank being empty. If there is a lack of water supply, the system will be dysfunctional when required, such as failing to extinguish the fire and thus, resulting a significant risk in safety and high-asset applications. Organisations such as the Maritime and Coastguard Agency (MCA) have called for the correct installation and maintenance of Water Mist systems.

For a system that fully relies on the supply of pressurized water, if there is no availability of this source of water, there is no possibility of fire depletion exemplified by the MCA: “effective fire-fighting can only be achieved when the water mist is released promptly on demand.” This is demanded by the IMO regulations MSC.1/Circ 1432, Ch 5.4: “Verify that sprinkler pressure tanks or other means have correct levels of water”. Further to the NFPA 750 regulations state that “Water Storage Vessels must be equipped with a means of checking the level of water inside during a weekly or monthly inspection. Some high-pressure storage cylinders do not have a means to confirm water levels. If such cylinders are present in a system, extra measures should be implemented.” There is an industry wide recognition that these cylinders need monitoring for the safety of the crew and vessel. Ultrasonics is an innovative technology to answer this call.

To ensure that Water Mist systems are fully operational in the event of a fire, and to avoid the serious risk of empty cylinders, the liquid level of the cylinders should be checked non-invasively using ultrasound. One of the sciences being harnessed by innovators in the fire safety sector is that of Ultrasound: i.e. acoustic (sound) energy in the form of waves of high frequency that are above the human audible range. By utilising a sensor which acts as a transceiver, an ultrasonic measuring device is capable of detecting liquid levels within any single-skinned container through transmitting an ultrasonic pulse and analysing the strength of the returned signal to determine the level of contents. As sound behaves differently in air and liquid, so will the strength of the returned signal be different in the liquid allowing us to identify the level of contents accurately.

Better maintenance of water mist fire suppression systems will save lives. Innovative ultrasonic technology enables the crew to be in full compliance of the regulations at all time, delivering a Safeship to protect the lives of crew/passengers/cargo and vessel, quicker, better and more effectively than other traditional methods.

Why use ultrasound to test for watertightness?

Proper definitions of watertightness are crucial for proper maintenance of seals.

Watertightness and airtightness could be defined mathematically, using this formula for approximating the flow rate Q through an aperture: 

Q = the flow rate of fluid through the aperture (where the term ‘fluid’ here is taken to mean an ideal liquid or gas)
A = is the area of the leak aperture
g = the acceleration due to gravity acting on the fluid, and
h = the head of fluid.

This equation (which contains simplifications) is used to demonstrate how since no two meeting surfaces in a seal can ever truly be perfectly aligned, a leak aperture will always exist which will allow leaking of some rate under a head of water. Watertightness is hence defined as a maximum water leakage allowance per minute.
High pressure watertight doors are designed for pressures in excess of 100' (30.5m) (this is equivalent to to a pressure of 299 kPa/ or 3 bar). Typical applications include protection for ship power plants, high-pressure chambers, hydro-electric plants and diving/decompression chambers which are often found on oil platforms and support vessels. In these sensitive areas a small 1m2 watertight door is often expected to be able to resist the weight of 30 tonnes of water without buckling or allowing the protected compartment to flood, and as such the requirement for frequent and accurate preventative maintenance on these seals cannot be overstated.

Ultrasonic Testing of seals

Ultrasonic Technology is being rapidly adopted as a safe, easy and accurate method of identifying seal leak sites and has been quickly adopted by the Royal Navy to quickly identify any incorrectly installed MCT's. UT equipment has now been in service for 3 years aboard HMS Albion and HMS Bulwark, and has also recently been adopted this year by the Indian Navy, and Indian Coast Guard.

Different models of equipment vary, but in general UT equipment consists of two main units; a generator and a receiver. The generator produces an ultrasonic modulated tone, usually at a round 40kHz which is positioned on one side of the seal. The receiver is then used by the operator from the far side of the closed seal. If at any point the seal is imperfect, the ultrasonic signal will be able to pass though the seal through the leak, which can then be detected by the receiver. Some models of ultrasonic watertight compartment doors testing are capable of detecting leak apertures as small as 0.06±0.02mm in size. UT testing seals can provide the sensitivity to detect the smallest leaks, and can give two different types of readout scale: linear and decibel. The linear scale provides an intuitive measurement of the leak size, whereas the decibel scale allows for comparison of standards set by international classification societies. Use of UT is far more efficient that the methods described above, taking less time, requiring no clean up and is used in a portable, light-weight model for ease of use. Due to its convenience, UT tests can be conducted more frequently and can contribute to safety management and preventative maintenance procedures on board. Moreover, the accuracy of this method is unrivalled, and leak sites can be identified and specifically located quickly for the operator. Furthermore, ultrasonic indicators use safe and green technology; it that does not violate any environmental codes, which also means there are no IATA transportation restrictions

C.S.P. Hunter, G.H.C. Hunter, C.M.E. Hunter, S. Watson, J. O’Connor, ‘2016 sees hatch cover watertight integrity testing extended to 24/7 continuous monitoring&2020 look ahead to vessel system
Integration and shore-based data management’, RINA Smart Ships Conference, 2015

Why chose the Portalevel® MINI Nippon?

The Portalevel® Mini Nippon was created specially to serve the unique requirements of our Japanese Customer base. Using our well-proven 7th generation technological platform, it was specially adapted to manage the challenging Japanese manufactured cylinders. Providing users with hands-free operation for ease of use and highly reliable unit, it offers an ideal solution for inspecting CO2 Fixed Fire Suppression Systems.

Technical Specifications of Portalevel Mini Nippon

Here, we have enlisted technical specs available with this liquid level detector. Give it a look!

Dimensions

  • Height: 98mm
  • Weight: 45.5grams
  • Width: 158mm
  • Depth: 420mm

Accuracy

+/-1.5mm (1/8 inch)

Power Supply

4 x AA 1.5V Batteries (battery life 10 hours)

Sensor

TX/RX Dry Sensor

  • Contained within a magnetized sensor applicator;
  • 14 mm diameter head
  • Connected by BNC connectors to 1 m length co-ax cable

Standard Extension Rod Sensor

  • Connected by bnC connectors to 1 m length co-ax cable.
  • 28mm in diameter
  • 1 meter in length

Verifiable Agents

CO2, H20, FM-200™, NOVEC™1230, old Halons such as 1301 and 1211, FE-13™, FE-25™, FE-36™, HFC-225 & 2271

Display

LCD Numeric Digital Display with LED Bar Graph

Classification

  • NATO Stock Number: 6680-99-275-5292
  • IP Rating 65

Certificates

  • Classification Society Approved- RINA
  • ISO 19011 Registered
  • CE

Warranty

  • Lifetime Customer Support
  • Sensor: 1 Year Warranty
  • Main Unit: 3 Years Warranty

Operating Temperature

  • Relative Humidity-5 % - 95 %
  • -20°C to +70°C (68°F to 158°F)

Portalevel Mini Nippon Content

  • 1 Hard Wearing Carrying Case
  • 1 Portalevel® Mini Nippon unit
  • 1 28 mm Extension Rod
  • Calibration certificate
  • 1 Wet Sensor
  • Ultrasonic Gel

Portascanner® WATERTIGHT: What is in the package?

The Portascanner® WATERTIGHT is made up of a generator and receiver. The receiver is capable of receiving the signals and conversion is made which results into the indication of W/T integrity. Portascanner® WATERTIGHT is multiple cable transit areas testing device.

What is in the Portascanner® Watertight package?
It consists of extension rod connector, Gain 1,2,3, Volume Up and Down Buttons, LCD Visual Display, Mode, On and Off Buttons and Headphone Connection. It is tuned for detecting the particular frequency of ultrasound ways.

  • It possesses audio and visual outputs.
  • Sensor rod is attached to it, a user can scan the seal at close range.
  • LCD screen shows the visual output of detected signal.
  • The visual data received can be converted to decibels (dB) reading which is perfect to be tested to certification society standards.
  • Bar graph representation is also available.
  • With standard jack of 3.5 mm, a headphone is attached to the receiver to receive audio signals.

The operation of  the generator of the cable transit watertight areas testing is mentioned below:

  • It is placed on one side of the sealed compartment and turned on.
  • Sensor rod is utilized to scan the seal by user, standing on the other side of the compartment
  • Increased signal strength will be shown apparently for leak sites.
  • The numerical display and volume of audible signals can easily show the strength of the signals received by the receiver.

Continuous Monitoring of Fire Suppression Systems

The regulations are not extensive enough to deal with the risks presented in gaseous systems. In ISO 14520 which is the “gold standard” of clean agent fire suppression system, clauses 9.2.1.3 in the regulations explains that the storage container contents shall be checked at least every six months as follows. : a) Liquefied gases: for halocarbon agents, if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure (adjusted for temperature) of more than 10 %, it shall be refilled or replaced. b) Non-liquefied gases: for inert gas agents, pressure is an indication of agent quantity. If a container shows a loss of agent quantity or a loss of pressure (adjusted for temperature) of more than 5 %, it shall be refilled or replaced. Essentially, the regulations highlight the need for periodic maintenance because it is known that the gaseous systems leak and need to be periodically checked. Given that the gaseous systems are designed specifically to the individual need of that enclosure, a 5% loss of agent may mean that they would not fully extinguish the fire.

Coltraco have developed a fixed fire suppression monitoring device, the Permalevel® MULTIPLEX which is designed for permanent contents verification. The continuous monitoring system utilises ultrasound technology to detect the level of contents non-invasively and transmits the level information from the wired sensors to the main unit which is then processed and reported to the building’s BMS or local control panel wirelessly through TCP/IP. This is to ensure that FM 200 fire suppression systems are always   stored at their designed concentration and that no accidental discharge has occurred, which could affect the effectiveness of the overall fire protection system in the event of a fire. The neglect of continuous monitoring - of the fundamental protection provided by the gaseous extinguishing systems - is to the peril of the lives of occupants of the premises and at the risk of causing financial and reputational loss to the facility comprising the critical infrastructure.

The system developed utilises the Internet of Things (IoT) to achieve its full potential of visualising the monitored contents worldwide. IoT enables a worldwide transmission of data starting from sensor to sensor to the microprocessors and to the facilities manager or maintenance team. Instead of waiting for annual checks, owners and building managers can now identify any changes to their installed fire suppression system contents in real time and dispatch their servicing or maintenance team as soon as notification is received about a change happening to the installed system. This is now entirely possible through the reliance on recent IoT developments.

The Ungoverned Space of Marine Fire Safety

Over the last few decades cargo has generally been increasingly transported in containers rather than as open bulk cargo, thus mistakenly leading shipping companies to disregard the importance of fire protection systems, instead focusing on transporting greater quantities facilitated by the container system. However, this outlook is dangerous and misplaced. The risk of fire is significant with growing incidences of fire events exposed in the trade press, posing a risk both to expensive cargo and to human life on-board the ships. With a movement towards autonomous shipping systems and smart-ships, the importance of remotely monitored fire-fighting systems could grow exponentially, providing the opportunity to monitor vessels from an external location. Technological developments and companies such as Coltraco Ultrasonics, are working towards this end goal. The current on-board fire-fighting facilities remain inadequate in the face of the capacity of such large vessels. Fire therefore remains an ever-present risk on the high seas.

Traditionally, the maritime industry treats fire protection systems as a necessary expenditure, rather than a means to safeguard valuable crew and cargo and maintain business continuity of the vessel. Owners focus on systems delivered at the most competitive rates rather than seeing fire protection as an investment.  The definition of a free market is an idealised form of a market economy in which buyers and sellers are allowed to transact freely based on a mutual agreement on price without state intervention in the form of taxes, subsidies or regulation. The competitiveness of the free market places great pressure on cost cutting: to deliver systems which often only minimally comply with regulations, and deliver asset protection at the most economical budget. With the value of assets, vessels and importance of business continuity growing, insurers are asked to underwrite almost incalculably high risk.  Unquestionably, the first priority of fire safety systems is to protect human life. Having said that, the economic benefits of a truly integrated, continuous, ultrasonic monitoring system in the future would be significant. Cargo damage remains an important negative result of on-ship fires, with 2 of the top 5 most expensive cargo claims on container ships in the last 10 years being fire-related according to the Swedish P&I Club Claims Analysis (2016). Fire protection measures should hence be understood as a worthwhile business investment. Yet we accept minimally compliant fire systems. Given both the crew lives and cargo are at stake, it seems unfathomable that regulations do not mandate fire systems should be permanently monitored rather than certified typically just once a year, if that, particularly since it is a regulatory obligation and or recommendation to ensure that crew can check these themselves.

Who would build a ship or offshore platform and install a power generating or auxiliary machinery without installing emergency power systems or monitoring their condition states? Who today would consider installing an alarm system without monitoring its overall status, not only its actuation, and integrating the whole system into the ship safety management system, with central monitoring being an essential part of it? These are basic engineering principles: building in redundancy and constantly monitoring critical systems. 

Traditionally, the industry cares little about this ungoverned space, with too few qualified engineers considered subject matter experts. Yet when it comes to marine fire maintenance, never mind continuous monitoring, of gaseous fire extinguishing systems, there is a lack of knowledge amongst the majority of the industry, regarding the potential risks. Awareness should exist about the huge expenses incurred by fire, both in terms of costs upfront from the damage and long-term due to reputation and unknown losses or damage to seafarers, vessel integrity, and cost of downtime and recovery. Above all is the risk to human life presented by fire. Poor maintenance of suppression systems risk accidental fatalities due to lack of training about the lethal properties of CO2 & Marine CO2 Systems (the predominant suppressant agent used on vessels, because it is the cheapest whilst being highly effective): when released it reduces oxygen levels to extinguish fire. Limited appreciation of the need for room integrity testing of protected spaces leads to minimal regulation compliance which could mean a failure of the fire system suppressing a fire because the room is unable to hold the discharged gas due to leaks of the space into which it actuates.

Gaseous extinguishing/suppression systems are installed to protect against special hazards in critical infrastructure at sea. They deliver the infrastructure resilience our advanced maritime society requires. If the hazard is special and the vessel is critical, then this is the case for the constant monitoring of the fire systems that aim to deliver their protection. There is a lack of knowledge of the characteristics of the various extinguishants and the types of fire for which they are suitable. For too many years the industry has been left to too few brilliant experts to determine safe outcome.

Two broad categories of ship and offshore extinguishing systems exist: sprinkler systems and pressurized gaseous systems. While the former can suffer leakage, the latter can cause catastrophic effect due to their pressures. These large gas cylinders are pressurised liquefied gases or non-liquefied gases that are pressurized on actuation. CO2 is permanently under 720 psi or 49 bar of pressure i.e. nearly 50 times atmospheric pressure (by comparison a cup of water at sea level exists at 1 bar or 14.5 psi). Its’ state changes under increased temperatures to one that is neither a liquid nor a gas. Gases under pressure are often effectively considered by the industry as single and passive cylinder columns of solid material from the perspective of their monitoring following installation. Whereas being under pressure and constantly changing under temperature they should be considered as active and dynamic systems requiring constant monitoring. These are not passive systems therefore; they are dynamic ones, and all dynamic systems under pressure need constant monitoring to ensure their effectiveness and longevity. An engineered marine fire system typically lasts 20 years, longer than some vessels! 

Fire Innovation of the Year 2018: Portasteele® Calculator

Traditionally cylinders are manually weighed by turning off and dismantling each one, which may be risky and takes on average two people 15 minutes per cylinder.

To solve this problem, Coltraco Ultrasonics developed the innovative 8th generation Portalevel® MAX:  handheld ultrasonic liquid level indicator to inspect CO2, clean agents and more liquefied gaseous agents, by one person in just 30 seconds. Combined with the Portasteele® CALCULATOR these liquid level heights are converted into the weight of agent. This tablet based advanced calculator application is the first in the world to provide agent weight readings without physically weighing the cylinders to comply with regulations.

It is the first level indication method to take account of the temperature affect on the agent height. PortasteeleÒ CALCULATOR provides instant real-time results which can be recorded then emailed directly for datalogged audit trail. By replacing the use of manual calculation and formulae, Portasteele® CALCULATOR makes the whole process of fire suppression system servicing simple and effective.

This is a safer, more efficient and cost saving method to service fire cylinders. The technological innovation ensures an entirely user friendly and industry leading device.

See the Portasteele® CALCULATOR Here:

Calibrating your equipment annually or every 5 years? Regulation or recommendation?

Beware the Cost of Cheaper Price.

The argument goes that the cost of calibration should be in proportion to their acquisition price but this holds no inherent engineering logic as the reason for its calibration is contained in ISO 17025 which is an international standard. If manufacturers making measuring instruments base their calibration standards on laboratory ones then surety of safe practice will accrue to all its users globally. To dictate their own calibration standards as less regular than annually, as many do, is an indicator of potential doubt in their approach to delivering quality.

We are often asked about calibration, why it is important, how often it should be done and why. The reason we know calibration to be important, and recommend its annual frequency is because our equipment is designed to improve safety and best practice. Ensuring the equipment used by crew/technicians/engineers to conduct such inspections is accurate and calibrated is a necessary one. Our manufacturer’s recommendations are based on the best that exist in ISO 17025 – an international standard for the calibration of any monitoring or measuring equipment: it must be at least once a year.

Calibrating measurement instrumentation is vital for business continuity through improved maintenance procedures for all industries, yet the calibration of such equipment is not commonly discussed. All good companies will comply with calibration requirements, understanding the need to ensure their equipment works as designed. Yet negligence is commonplace due to lack of understanding of the value of calibrations and not knowing the regulations.

Here are some examples of best practice. At Rolls Royce the test cell for their Trent XWB engines are calibrated every 3 months. In the gas industry, customers are recommended to calibrate their detectors every 6 months, especially if they are using them in confined spaces, in order to ensure they are maintaining their accuracy as per technical specifications. There are serious consequences if customers do not value the understanding of their monitoring or measuring tools or equipment, which unfortunately renders them at risk.

But, what about 5 year calibration certificates? On calibration and as a manufacturer of quality, we are clear that it is unsound, unsafe and unprofessional to compete on calibration cost as some competitors offer 5 year calibration certificates. How can the manufacturer know its calibration will hold given the array of climate, humidity and environmental conditions that a product may go through 365 days per year ? We wish to uphold the best there is in ISO 17025. Nor do we wish customers to believe that it is the manufacturer who dictates calibration standards, which is not the case – the key here is that we will not issue calibration certificates beyond a year.

When you buy from any premier manufacturer, you have confidence in the longevity of your equipment, aided in our case by our Coltraco Customer Total Care Commitment, which includes life-time support. In addition, we have set up ODA Service Centers at major ports and centers worldwide, so our customers can send equipment for its calibration quickly and locally. We always do something “over and above” to enhance the unit for customers during its calibration and we have a wonderful reputation as a consequence.

So whilst we can enjoy the benefits of globalization that should not be limited to price attraction in isolation from the costs of cheaper prices. If you are buying something critical to your Safety Management System, forego the attractions of the cheaper price or scant regard for calibration standards that all too often accompany them.

Global trade depends on professionals across many industries to deliver it safely and to the highest standards, regardless of any cyclical down-turn. It is why we work so hard to develop our Safety Management Systems. They deliver Safe site® and Safe ship® practices, protecting life at sea, the vessel and its cargo. If we react to the cost advantages of poorly made and replicated equipment by buying them we should not be surprised if we also react to the allure those same manufacturers offer in regard to their servicing and calibration, and at that point the collective efforts of the governments, classification societies, trade associations and industry leaders striving for best practice will in itself be damaged.

Test Your Fire Suppression Systems

The fire industry calling is a noble one. It is uses scientific principles to enable its very existence. The fire industry, however, calculates fire engineering designs based on formulas that its technicians have no way of understanding or verifying are accurate. The industry needs a Resident Mathematician to ensure that the formulas they use are correct. Fire engineers do not always understand the physical properties of the clean agents they use. Some do not wholly appreciate the impact of temperature on the state of an agent or its pressures. Novec™ 1230 for instance is an organic compound which deteriorates quickly to a point of non-effectiveness if poorly handled and stored. These problems and many more can be solved in the fire industry by the application of fundamental scientific and engineering principles. But they can only be proved by the application of the mathematics of them. Coltraco are at the vanguard of this in the fire industry.

Are pressurised liquefied gases or non-liquefied gases that are pressurised on actuation. CO2 is permanently under 720 psi or 49 bar of pressure ie nearly 50 times atmospheric pressure (by comparison a cup of water at sea level exists at 1 bar or 14.5 psi). Its state changes under increased temperatures to one that is neither a liquid nor a gas. Gases under pressure are often effectively considered by the industry as single and passive cylinder columns of solid material from the perspective of their monitoring following installation. Whereas being under pressure and constantly changing under temperature they should be considered as active and dynamic systems requiring constant monitoring. These are not passive systems therefore; they are dynamic ones, and all dynamic systems under pressure need constant monitoring.  

By our ability to establish the liquid contents of liquefied clean agents – through UL-approved Portalevel™ MAX and the constant monitoring system, Permalevel™ Multiplex. Once we do this we can establish their weight and mass – through Portasteele™ Calculator (the world’s first product capable of this). If we can monitor their pressure too then we can monitor both the pressure of the gas above the liquefied agent such as in Novec™ 1230 and the pressure of non-liquefied gases such as Inergen or Nitrogen.

 

CEO Message

Integrity and Science Key to Our Culture of Performance

Dear Coltraco Customers, Strategic Partners and Distributors,

Integrity is our defining value. Performance is its consequence. We understand that our customers have choices, and how we perform determines whether customers choose us. Coltraco’s Code of Ethics does not merely require compliance with laws. It embodies a Commitment to positive behaviours that build trust, promote respect, operate with distinction, with courtesy and global levels of performance, demonstrating our integrity and delivering customer performance.

We honour our commitments, communicate transparently, and act with honour. Ethics are the foundation of our performance culture and our science-based approach. We lead in specific technologies delivering the watertight integrity monitoring of marine structures and the monitoring of fixed liquefied gaseous fire extinguishing systems and the room integrity of protected space to ensure agent hold-times post-installation. We show this by our understanding of the science in them and the mathematics that explain them.

I would like to thank you for your business and for the relationships with our Customers, Strategic Partners, Distributors and ODAs who we value so highly.

My kindest regards,
Carl

Carl Stephen Patrick Hunter BA(Dunelm) Hon DSc FRINA FIMarEST MRAeS
CEO & Managing Director
Coltraco Ultrasonics Limited
46-47 Mount Street, Mayfair, London W1K 2SA
United Kingdom

Tel:  +44 20 7629 8475
Fax: +44 20 7629 8477

Call Now : +44 207 629 8475

 

References in PDF Format

 

Underwriters LaboratoriesUnderwriters Laboratories

 

Reference Alpha Fire UK Portalevel MAX Sept 2012

Reference Portascanner-II CSD MOD Albion and Bulwark

Quotation.

Quotation

Support.

Support

About Coltraco Ltd.

About

 
 

Request a Quotation

Online Submission

Click Here

Call: +44 207 629 8475

Our customer support line is open during UK
business hours
Mon-Friday, 9.00am - 5.00pm GMT

Email: sales@coltraco.co.uk

Enquire via email and a dedicated
member of the sales team will deal
with your request personally.

Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.