Efficient Portalevel Max

Coltraco Commitment To :

  • Through-life maintenance support
  • We still maintain units built 20 years ago
  • Extend trade-in credits - replace old units for new
  • UL listing & ABS type approval - Portalevel™ MAX
  • ABS type approval & RINA approval - Portascanner™
  • Be a life-safety technology partner – Permalevel™
  • Certified OEM calibration & ODA service stations

Coltraco manufacture Ultrasonics That Work

Efficient Portalevel Max

In the names in the world of ultrasonic monitoring devices, Coltraco Limited, UK is regarded to be an industry leader because of its accuracy. The R&D team work on the continued development of the technology. The prices are also kept reasonable and provide maximum output of the investment.

The Portalevel® MAX has been specifically designed to be as easy, simple and definitive for a user to operate as possible. Simple touch buttons now operate the controls and a new digital screen provides clear and definitive results to the user. The 7 steps below outline the simple testing process. Further technical support is available to all users for the life-time of the equipment if required.

  1. Attach the sensor to the main Portalevel® MAX, switch the unit on and ensure the “Battery Low” Indication is not showing.
  2. Depending on the condition of the cylinder, some couplet may need to be applied to the side of the cylinder, this could be in the form of Water spray, Ultrasonic Gel or an Oil & Water mix depending on what is easily accessible. This is not always essential and they all accomplish the required results.
  3. Place the senor towards the top of the cylinder and engage the “CAL” feature. This will set the unit to that particular cylinder, catering for the material thickness, paint or surface covering.
  4. When engaging the “CAL” feature, the Bar Graph on the screen will extend all the way to the right and the numbers will read high values.
  5. The user should then move the sensor down the cylinder in small steps, making sure not to drag the sensor down the cylinder face.
  6. When the sensor passes the level mark, the numbers will drop dramatically and the Bar graph will reduce all the way to the left. It is this change in display readings which identifies the difference between Air (above Level) and Liquid (below Level) in a cylinder.
  7. Through moving the sensor up in smaller steps, one can accurately pinpoint the exact liquid level location.

Graphical Presentation of Portalevel Max 8th Generation

This liquid level indicator is designed primarily to meet your measuring requirements of liquid levels enclosed in cylinders.

Approvals for Coltraco Ultrasonic Level Indicator

Moreover, for your convenience and comfort, we have mentioned the list of approvals this device possesses:

  • Assembled under IPC-A-610 American national standards, institute protocols and Full ESD electrostatic discharge protocols; Finished with lead-free Rohs compliant Tin/Copper SN100C patented solder
  • Environmental metal enclosure rated to IP65
  • UL Approved and Certified manufactured Circuit Boards to UL specifications
  • RINA Classification Society Approved
  • UK Government CAGE Code KD983
  • P/N: 2290334-COMX
  • UL Approval Certificate Number: 20140310-E455148

To know more about Portalevel Max 8th Generation, download PDF

 

CEO Message

Integrity and Science Key to Our Culture of Performance

Dear Coltraco Customers, Strategic Partners and Distributors,

Integrity is our defining value. Performance is its consequence. We understand that our customers have choices, and how we perform determines whether customers choose us. Coltraco’s Code of Ethics does not merely require compliance with laws. It embodies a Commitment to positive behaviours that build trust, promote respect, operate with distinction, with courtesy and global levels of performance, demonstrating our integrity and delivering customer performance.

We honour our commitments, communicate transparently, and act with honour. Ethics are the foundation of our performance culture and our science-based approach. We lead in specific technologies delivering the watertight integrity monitoring of marine structures and the monitoring of fixed liquefied gaseous fire extinguishing systems and the room integrity of protected space to ensure agent hold-times post-installation. We show this by our understanding of the science in them and the mathematics that explain them.

I would like to thank you for your business and for the relationships with our Customers, Strategic Partners, Distributors and ODAs who we value so highly.

My kindest regards,
Carl

Carl Stephen Patrick Hunter BA(Dunelm) Hon DSc FRINA FIMarEST MRAeS
CEO & Managing Director
Coltraco Ultrasonics Limited
46-47 Mount Street, Mayfair, London W1K 2SA
United Kingdom

Tel:  +44 20 7629 8475
Fax: +44 20 7629 8477

Call Now : +44 207 629 8475

 

References in PDF Format

 

Underwriters LaboratoriesUnderwriters Laboratories

 

Reference Alpha Fire UK Portalevel MAX Sept 2012

Reference Portascanner-II CSD MOD Albion and Bulwark

Quotation.

Quotation

Support.

Support

About Coltraco Ltd.

About

 
 

Request a Quotation

Online Submission

Click Here

Call: +44 207 629 8475
Our customer support line is open during UK
business hours
Mon-Friday, 9.00am - 5.00pm GMT

Email: sales@coltraco.co.uk
Enquire via email and a dedicated
member of the sales team will deal
with your request personally.