Comply with IMO SOLAS & FSS Codes

Coltraco Commitment To :

  • Through-life maintenance support
  • We still maintain units built 20 years ago
  • Extend trade-in credits - replace old units for new
  • UL listing & ABS type approval - Portalevel™ MAX
  • ABS type approval & RINA approval - Portascanner™
  • Be a life-safety technology partner – Permalevel™
  • Certified OEM calibration & ODA service stations

Coltraco manufacture Ultrasonics That Work

Comply with IMO SOLAS & FSS Codes

Fires on board ferries can be devastating, to crew, vessel and cargo. There is a call to respond to regulations with a rigorous attitude, to go above and beyond, to provide security of life and infrastructure

Misunderstanding exists across parts of the ferry industry regarding the application of a part of the International Maritime Organisation, Safety of Life at Sea, Fire Safety Systems (IMO SOLAS FSS) Code; the need for crew to test the contents of their CO2, FM 200 fire suppression system® & NOVEC™ 1230 Gaseous Extinguishing Systems in between the periodic inspection, maintenance and certification intervals.

IMO SOLAS & FSS Code Chapter 2.1.1.3 - “Means shall be provided for the crew to safely check the quantity of the fire extinguishing medium in the containers.”

The reason the IMO requires crew to test for contents in-between these is that the “ferries sails alone”; it must act as its own emergency fire service. 

A ferries’s gaseous extinguishing system typically comprises between 200 and 600 cylinders each containing 45KG of CO2 under high 720 psi/ 49 bar pressure. Some marine service companies estimate that 20% of a ferries CO2 cylinders have discharged or partially leaked their contents at some point in their lifetime. Yet although this poses high levels of risk to the service companies and the crew, because gaseous extinguishing systems are highly pressurised, the risk of leaking and discharging is accepted as part of their use and this is shown in the regulations that demand their upkeep.

Using an ultrasonic liquid level indicator is the only way that the crew can safely test their CO2 & marine CO2 systems without disturbing them. If ferry companies implemented the IMO SOLAS FSS codes by testing safely and quickly (just 30-60 seconds per cylinder) by using liquid level indicators and marine servicing companies were able to do their work without allowing for time pressures, then marine safety would be far safer.

Any vessel with a Marine Gaseous Extinguishing system needs to consider 3 factors :

  • Unless compartmentation exists the gas will not be able to concentrate
  • Unless the contents exists in sufficient quantity design concentration will not occur
  • The pipework and flanges must be tested to be free of corrosion-generated particulates which block the nozzles and must be tested to be able to withstand the shock of gas discharge on actuation

 

CEO Message

Integrity and Science Key to Our Culture of Performance

Dear Coltraco Customers, Strategic Partners and Distributors,

Integrity is our defining value. Performance is its consequence. We understand that our customers have choices, and how we perform determines whether customers choose us. Coltraco’s Code of Ethics does not merely require compliance with laws. It embodies a Commitment to positive behaviours that build trust, promote respect, operate with distinction, with courtesy and global levels of performance, demonstrating our integrity and delivering customer performance.

We honour our commitments, communicate transparently, and act with honour. Ethics are the foundation of our performance culture and our science-based approach. We lead in specific technologies delivering the watertight integrity monitoring of marine structures and the monitoring of fixed liquefied gaseous fire extinguishing systems and the room integrity of protected space to ensure agent hold-times post-installation. We show this by our understanding of the science in them and the mathematics that explain them.

I would like to thank you for your business and for the relationships with our Customers, Strategic Partners, Distributors and ODAs who we value so highly.

My kindest regards,
Carl

Carl Stephen Patrick Hunter BA(Dunelm) Hon DSc FRINA FIMarEST MRAeS
CEO & Managing Director
Coltraco Ultrasonics Limited
46-47 Mount Street, Mayfair, London W1K 2SA
United Kingdom

Tel:  +44 20 7629 8475
Fax: +44 20 7629 8477

Call Now : +44 207 629 8475

 

References in PDF Format

 

Underwriters LaboratoriesUnderwriters Laboratories

 

Reference Alpha Fire UK Portalevel MAX Sept 2012

Reference Portascanner-II CSD MOD Albion and Bulwark

Quotation.

Quotation

Support.

Support

About Coltraco Ltd.

About

 
 

Request a Quotation

Online Submission

Click Here

Call: +44 207 629 8475

Our customer support line is open during UK
business hours
Mon-Friday, 9.00am - 5.00pm GMT

Email: sales@coltraco.co.uk

Enquire via email and a dedicated
member of the sales team will deal
with your request personally.

Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.