Are annual checks of gaseous suppression systems enough?

Wind power is an exciting emerging sector that needs those of us involved in fire safety to get on board. As electricity generation becomes more reliant on renewable energy, wind power is becoming increasingly important in the energy mix. As our reliance on wind turbines grows, keeping them fully operational and at reduced levels of risk is becoming more important, and as a result, so is safety management. There are over 340,000 wind turbines around the world; yet the vast majority of turbines have no fire suppression system installed.
The fires in wind turbines not only lead to a loss of business continuity and a negative impact on the company’s reputation but also, most importantly, are a critical safety issue. Possibly harmful debris can drift into the wind in the event of a fire and there is also a significant risk to human lives. When turbines are under construction, commissioning maintenance and repair, escape routes for operators are often long and vertical.

A recent report found that three out of six incidents studied involved a human presence in the nacelle*3; hence, a fire becomes a safety concern.  In 2013, a crew of four engineers died in Ooltgensplaat, Netherlands in a wind turbine fire. This devastating loss of life calls for improved review of fire safety to minimise the risk to engineers.

Fire is the second leading cause of accidents in wind turbines after blade failure1.

Most wind farms are in remote locations, and wind turbines are designed with the mechanical portion – where most fires start - nearly 300ft off the ground at the top in the nacelle. There is simply no practical way to respond to a fire in these units, meaning that when one occurs, the typical action is simply to wait for it to burn out.

With the average overall cost of a wind turbine fire being around $4.5m2, and given that $112.5bn was ploughed into wind power globally in 20163, turbine owners – and authorities - are increasingly seeing the prudence of investing in fire suppression.

Since 2011 there have been 36 large wind turbine fire incidents reported in the mainstream media, although the actual number is much higher, with many smaller, less visible fires going unreported. Most recently, in Wyoming in the US last September, a wind turbine blaze caused a wild fire that burned out nearly 1,600 acres.

There are three main causes of wind turbine fires: mechanical failure, electrical malfunction and lightning strikes. These pose a uniquely high risk due to both the turbines’ exposed locations and their height; turbines are now being built in excess of 450ft.

Even a small fire can accelerate quickly in a nacelle that comprises highly flammable resin fibreglass. Internal insulation, which can become contaminated by oil deposits, further adds to the fuel load.

Redesigning the turbines to reduce the fuel load inside the nacelle is one step to reduce fire risk. In addition, any maintenance and repair activities that involve ‘hot work’ inside the nacelle could be avoided. It has also been suggested that condition monitoring systems should be implemented and maintenance checks completed regularly.

As a final step, automatic fire detection and suppression systems can be incorporated to further protect the nacelle, which presents a unique challenge: dust, vibration and temperature fluctuations can all interfere with reliable operation.

There are several types of fire detection available. Smoke detection or air sampling systems can be successful at detecting the early stages of a fire, but may be rendered ineffective by air flows and environment. Alternatively, traditional linear heat detection systems and fusible link detection systems aren’t affected by air and dust but are potentially electrically conductive. Significantly, all these systems will fail if the external power or battery backup fails. 

Then there are the fire suppression agents. Compressed air foam systems and water mist are potentially corrosive and can be ineffective on energized electrical components.

Carbon dioxide systems aren’t ideal because, due to the CO2 displacing the oxygen in the event of a discharge, the fire suppression system has to be ‘locked out’ any time personnel are present in the nacelle. In a working at height situation this is a major safety concern.

The weight of these technologies and the space required to store them can also pose a problem in the cramped environment within the nacelle.

The most common solution today overcomes the above drawbacks by providing component-level automatic systems that offer both fire detection and suppression in a single package. Designed to detect a small fire in or around a critical component, they dramatically improve the response time and reliability while reducing the size of the system required.

These systems use clean agent fire suppression technology involving a non-conductive gas, which leaves no residue following a discharge, requires no clean up, and in small volumes doesn’t present a hazard to personnel.

The presence of an automatic fire detection and suppression system like Firetrace offers 24/7 reliability and unsupervised protection to quickly address a growing fire and limit its damage.

And yet, despite the availability of affordable fire suppression methods, thousands of wind turbines are still being installed without adequate fire protection, and entirely preventable wind turbine fires continue to occur.

There has, however, been increasing momentum over the past few years for legislation requiring fire suppression on new wind farms. A growing list of authorities in Germany, and a number of both local and state governments in the US, are acknowledging that fire suppression is a judicious step to safeguard assets in the event of a fire in a wind turbine. A piece of unique regulation in Canada has taken it a step further, enabling local authorities to insist that fire suppression is retrofitted to existing sites.

This is a welcome trend. Designing in fixed fire suppression, which can contain the blaze within the micro-environment of the nacelle, is a logical move to help prevent large-scale fires.

However, it is important to note that such fire extinguishing systems require maintenance to ensure they are fully operational and ready in event of a fire. ISO 14520-1:2015(E) assumes that these systems accidentally discharge and leak. 6.2.4.2 Contents indication: “Means shall be provided to indicate that each container is correctly charged.” Followed by “9.2.1.3 The storage container contents shall be checked at least every six months as follows. a) Liquefied gases: for halocarbon agents, if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure (adjusted for temperature) of more than 10 %, it shall be refilled or replaced.”

Section 10.5.3.2.2. of the NFPA 850 states that the Maintenance and inspection of total flooding gaseous agent systems and interlocked equipment are critical. All systems at some time may be called upon to operate in an emergency situation and may help in saving life and property. It is for this reason that knowledge must be had that the system can operate to its full potential.

ARE ANNUAL CHECKS SUFFICIENT IN RISKY ENVIRONMENTS?

What if the suppression systems installed in the turbines to protect life and infrastructure do not release on actuation? Gaseous extinguishing/suppression systems are installed to protect against special hazards in critical infrastructure as their key objective. They deliver the infrastructural resilience that wind turbines require. If it is a known fact that there is a long response time to wind turbine fires, then it is unacceptable that the dynamic suppression systems are left unattended 364 days a year.

A CALL FOR CONSTANT MONITORING OF WIND TURBINES

A dynamic system needs monitoring.  The reality is that gaseous systems are checked for contents annually because they are pressurised and anything that is dynamic offers risk of loss of contents, but this fails to deal with the probability of discharge or leakage for the 364 days per annum in the interim between certification checks.

If the hazard is special and the infrastructure critical then this is the case for the constant monitoring of the suppression systems that aim to deliver the protection of them. Inspection should include an evaluation that the extinguishing system continues to provide adequate protection for the risk.

Coupled to this is a complete lack Room Integrity testing after the gaseous system has been installed. As buildings age or their internal use is changed leak sites develop. If the gas cannot be ‘held’ in the room on discharge during a fire event the probability of its suppression diminishes in direct proportion to the size of the leak sites.  Room integrity tests are imperative for the determination of both the hold time and the peak pressure needed for successful fire suppression.

The level of leakage is carefully monitored in order to ensure the correct agent concentration is achieved; room integrity must be ‘tight’ enough to ensure sufficient retention time according to NFPA Standards or ISO 14520, yet remain ‘loose’ enough to prevent enclosure damage at discharge.  The presence of undesired and unregulated leak sites reduces room integrity and will hence dramatically impact the hold time and peak pressure, placing room contents and potentially wall structures at risk.

It is accepted that in wind turbines vibration can loosen connections while dirt, dust, and temperature extremes are known to cause unwarranted discharge. Additionally, openings in the turbine housing significantly inhibit achieving the designated agent concentration. Devising a solution to overcome these challenges can add significantly to the weight in the turbine.

For regular inspection, there are solutions such as the Portalevel® MAX. This handheld ultrasonic liquid level indicator can service a cylinder in 30 seconds (in contrast to 15 minutes by traditional manual weighing) with accuracy of up to 1.5mm off the true liquid level.

Coltraco Ultrasonics provide smart Firetest® solutions that enable wind turbine owners and operators to improve their fire safety management and reduce the risks to human life, business continuity caused by any downtime and thus minimise risk to reputation by delivering a Safesite®.

 

CEO Message

Integrity and Science Key to Our Culture of Performance

Dear Coltraco Customers, Strategic Partners and Distributors,

Integrity is our defining value. Performance is its consequence. We understand that our customers have choices, and how we perform determines whether customers choose us. Coltraco’s Code of Ethics does not merely require compliance with laws. It embodies a Commitment to positive behaviours that build trust, promote respect, operate with distinction, with courtesy and global levels of performance, demonstrating our integrity and delivering customer performance.

We honour our commitments, communicate transparently, and act with honour. Ethics are the foundation of our performance culture and our science-based approach. We lead in specific technologies delivering the watertight integrity monitoring of marine structures and the monitoring of fixed liquefied gaseous fire extinguishing systems and the room integrity of protected space to ensure agent hold-times post-installation. We show this by our understanding of the science in them and the mathematics that explain them.

I would like to thank you for your business and for the relationships with our Customers, Strategic Partners, Distributors and ODAs who we value so highly.

My kindest regards,
Carl

Carl Stephen Patrick Hunter BA(Dunelm) Hon DSc FRINA FIMarEST MRAeS
CEO & Managing Director
Coltraco Ultrasonics Limited
46-47 Mount Street, Mayfair, London W1K 2SA
United Kingdom

Tel:  +44 20 7629 8475
Fax: +44 20 7629 8477

Call Now : +44 207 629 8475

 

References in PDF Format

 

Underwriters LaboratoriesUnderwriters Laboratories

 

Reference Alpha Fire UK Portalevel MAX Sept 2012

Reference Portascanner-II CSD MOD Albion and Bulwark

Quotation.

Quotation

Support.

Support

About Coltraco Ltd.

About

 
 

Request a Quotation

Online Submission

Click Here

Call: +44 207 629 8475
Our customer support line is open during UK
business hours
Mon-Friday, 9.00am - 5.00pm GMT

Email: sales@coltraco.co.uk
Enquire via email and a dedicated
member of the sales team will deal
with your request personally.

Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.