Continuous Monitoring is Essential

Coltraco Commitment To :

  • Through-life maintenance support
  • We still maintain units built 20 years ago
  • Extend trade-in credits - replace old units for new
  • UL listing & ABS type approval - Portalevel™ MAX
  • ABS type approval & RINA approval - Portascanner™
  • Be a life-safety technology partner – Permalevel™
  • Certified OEM calibration & ODA service stations

Coltraco manufacture Ultrasonics That Work

Continuous Monitoring is Essential

Continuous monitoring is no longer an option; it is essential for the protection against special hazards in critical infrastructure. Clean agents are designed to operate in limited spaces where there is a need for speed of suppression given the asset risk and where the space is occupied by people. They deliver the infrastructural resilience our advanced society requires. The assumptions in the installation, commissioning and maintenance of gaseous extinguishing systems is that they are highly pressurised but risk leaking and discharging. ISO 14520 specifically guides our industry as to these risks; In 9.2.1.3 The storage container contents shall be checked at least every six months as follows. : a) Liquefied gases: for halocarbon agents, if a container shows a loss of agent in quantity of more than 5 % or a loss of pressure (adjusted for temperature) of more than 10 %, it shall be refilled or replaced. b) Non-liquefied gases: for inert gas agents, pressure is an indication of agent quantity. If a container shows a loss of agent quantity or a loss of pressure (adjusted for temperature) of more than 5 %, it shall be refilled or replaced. Therefore, at a standards level it is known that gaseous systems can become ineffective through accidental discharge and leakage and thus they do not serve to protect the critical infrastructure in such a case. To know the contents, you need to monitor it, and checking it every 6 months is not monitoring it.

Should we not just constantly monitor all of them and be in full compliance to the regulations and the risks that are so clearly described in our own core standards? If it is known and accepted that these are dynamic systems that are prone to leaking, but they are expected to deliver resilience and protection, then why are they left unattended for 6 months of the year? We would not do the same to an alarm system without monitoring it 24/7, so why are we not monitoring gaseous extinguishing systems? Let us apply 21st century science to a 100 year old issue and be done with it. A dynamic system needs monitoring. The neglect of continuous monitoring of the fundamental protection provided by the gaseous extinguishing systems is to the peril of the lives of occupants of the premises and at the risk of crippling financial loss to the facility comprising the critical infrastructure. To ensure that dynamic gaseous systems are protecting critical infrastructure in a safe and diligent manner, 6 monthly monitoring and maintenance is no longer enough. There is a call for continuous monitoring and this is something that cannot wait any more.

 

CEO Message

Integrity and Science Key to Our Culture of Performance

Dear Coltraco Customers, Strategic Partners and Distributors,

Integrity is our defining value. Performance is its consequence. We understand that our customers have choices, and how we perform determines whether customers choose us. Coltraco’s Code of Ethics does not merely require compliance with laws. It embodies a Commitment to positive behaviours that build trust, promote respect, operate with distinction, with courtesy and global levels of performance, demonstrating our integrity and delivering customer performance.

We honour our commitments, communicate transparently, and act with honour. Ethics are the foundation of our performance culture and our science-based approach. We lead in specific technologies delivering the watertight integrity monitoring of marine structures and the monitoring of fixed liquefied gaseous fire extinguishing systems and the room integrity of protected space to ensure agent hold-times post-installation. We show this by our understanding of the science in them and the mathematics that explain them.

I would like to thank you for your business and for the relationships with our Customers, Strategic Partners, Distributors and ODAs who we value so highly.

My kindest regards,
Carl

Carl Stephen Patrick Hunter BA(Dunelm) Hon DSc FRINA FIMarEST MRAeS
CEO & Managing Director
Coltraco Ultrasonics Limited
46-47 Mount Street, Mayfair, London W1K 2SA
United Kingdom

Tel:  +44 20 7629 8475
Fax: +44 20 7629 8477

Call Now : +44 207 629 8475

 

References in PDF Format

 

Underwriters LaboratoriesUnderwriters Laboratories

 

Reference Alpha Fire UK Portalevel MAX Sept 2012

Reference Portascanner-II CSD MOD Albion and Bulwark

Quotation.

Quotation

Support.

Support

About Coltraco Ltd.

About

 
 

Request a Quotation

Online Submission

Click Here

Call: +44 207 629 8475
Our customer support line is open during UK
business hours
Mon-Friday, 9.00am - 5.00pm GMT

Email: sales@coltraco.co.uk
Enquire via email and a dedicated
member of the sales team will deal
with your request personally.

Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.